Gun short circuit current (sci) test, Ransburg, No. 2 process electric motor version - operation – Ransburg No. 2 Process Handgun Electric Motor User Manual
Page 25: No. 2 handgun short circuit current test diagram
No. 2 Process Electric Motor Version - Operation
Ransburg
21
AH-13-01.1
W A R N I N G
!
1
2
3
4
5
NO. 2 HANDGUN SHORT CIRCUIT CURRENT
TEST DIAGRAM
(Figure 14)
Item#
Description
9060 Digital µA Meter Readout
High Voltage Cable
19372 -XXX No. 2 Handgun
Earth Ground Connection to Brush
Microamp Meter or 76652 to Earth Ground
Gun Short Circuit Current
(SCI) Test
1. Connect wire at contact brush to ground via
microampere meter.
2. Activate the applicator by turning the switch to
the “ON” position to spin the electric motor and
initiate high voltage.
3. Read SCI on remote microampere meter:
• SCI = 90 to 115 microamperes.
4. If SCI is low or high, see “Paint, High Voltage &
SCI Test Equipment” manual for SCI test procedure
using test probe TE-98-01 Part number 76652.
Figure 14: No. 2 Handgun Short Circuit Current Test Diagram
All paints and solvents must be
purged from the applicator prior to per-
forming these tests.
- RCS 2 Ratio Control System (82 pages)
- DynaFlow Programmers Manual (59 pages)
- DynaFlow User Manual (100 pages)
- Vector Solo 79901 Waterborne RS90-WB (66 pages)
- Vector Solo 79900 Solventborne RS90-AS (64 pages)
- Vector_Solo Technical Manual (16 pages)
- Solo Installation & Set-Up Kit (8 pages)
- Vector Solo AA90 79698 (58 pages)
- Vector Solo 65KV 79965 Solventborne RS70-AS (60 pages)
- Vector R Series Classic 79503 R90 Solventborne (74 pages)
- Vector R Series Cascade 79500 R90 Solventborne (78 pages)
- Vector AA90 79580 Cascade (62 pages)
- No. 2 Spray Techniques (16 pages)
- No. 2 Air Motor Atex Approved Unit 80086-XX (63 pages)
- 9060 HV P.S. Air Motor 80102-31X (36 pages)
- 9060 HV P.S. Electric Motor 80102-21X (42 pages)
- REA Automatic Applicators 77359, 76110, 77140 (66 pages)
- Evolver SE Robotic Atomizer A12455-XXXXXXXX (79 pages)
- 9060 LV Auto Cascade 80120-XXX (56 pages)
- 9060 HV Auto Classic 80100-XXX (56 pages)
- Turbodisk Applicator Assembly A11376 (78 pages)
- Turbodisk Fairing Assembly 70158 (17 pages)
- MMA-303 Direct_Ind Test Stand (26 pages)
- MMA-303 Direct_Ind Charge Atomizer A12870 (132 pages)
- MMA-570 Direct_Ind Charge Atomizer A13366 (109 pages)
- Aerobell (Std.) Rotary Atomizer A12381 (89 pages)
- 9040 Aerobell Control Module 78387-00 (33 pages)
- Aerobell 33 AER5000, AER5001 (57 pages)
- Aerobell 168 A12787 (116 pages)
- Aerobell 168 Atex Approved 13350 (106 pages)
- RPA-2 Powder Applicator A12950-XXX (47 pages)
- RMA Indirect A11600 (103 pages)
- RMA Indirect A12869 (121 pages)
- Test Stand RMA-303, EVOLVER, EVOLVER NE (28 pages)
- RMA Dual Purge Direct A12300 (116 pages)
- RMA Dual Purge Direct A12868 (120 pages)
- RMA-560 Single_Dual Purge Direct A13364 (104 pages)
- RMA Direct A12867 (118 pages)
- Evolver Solvent Robot Applicator 79190-XXXXXXXX (82 pages)
- Evolver 303 Solvent Applicator A11976-XXX (85 pages)
- Evolver 303 Dual Purge Solvent Robotic Applicator A12374-XXX (86 pages)
- Evolver MicroPak Controller A10406 (37 pages)
- Voltage Master 2 78789_LEPS5001 (51 pages)
- PulseTrack2 A11515-XXXXX (58 pages)