Motor/Electrical
Install the motor according to NEC requirements and local
electrical codes. The motor should have an overload protec-
tion circuit.
Wire the motor for clockwise rotation when facing the fan
end of the motor.
CAUTION: Do not operate the pump to check rotation
until the pump is full of liquid.
Check all electrical connections with the wiring diagram
on the motor. Make sure the voltage, frequency, phase, and
amp draw comply with the supply circuit.
To verify correct rotation of the motor:
1. Install the pump into the system.
2. Remove the fill plug (items 2 & 2A) and fill the hous -
ing with 0.6 US gallon / 77 oz. (2.7 liters) of the service
liquid or water. Replace fill plug and tighten until the
o-ring is seated.
NOTE: Use a flexible spout funnel or a “tee” in the
discharge piping to fill the housing on pumps equipped
with flanges.
3. Fully open the suction and discharge valves.
4. Jog the motor (allow it to run for 1-2 seconds) and ob-
serve the rotation of the motor fan. Refer to the direc-
tional arrow molded into the front of the housing if
necessary.
NOTE: An SP pump running backwards may not
prime.
Section III - Start-up and Operation
1. Be sure the housing (item 1) has been filled with 0.6
US gallon / 77 oz. (2.7 liters) of service liquid and the
fill plug (item 2 & 2A) has been installed and tightened
until the o-ring is seated.
2. Open the inlet (suction) and outlet (discharge) valves
completely.
3. Turn the pump on. Wait for discharge pressure and flow
to stabilize (could take several minutes depending
upon suction lift). Adjust the flow rate and pressure by
regulating the discharge valve. Do not attempt to adjust
the flow with the suction valve.
Section IV - Shutdown
Turn off the motor.
NOTE: When the pump is stopped without a check valve
in the piping, liquid will flow through the pump returning
to the suction source. The SP design allows enough liquid
to be retained in the housing to allow repriming without
having to refill with liquid.
Flush Systems
CAUTION: Some fluids react with water; use compat-
ible flushing fluid.
1. Turn off the pump.
2. Completely close the suction and discharge valves.
3. Connect flushing fluid supply to flush inlet valve.
4. Connect flushing fluid drain to flush drain valve.
5. Open flushing inlet and outlet valves. Flush system
until the pump is clean.
NOTE: The drain can be used as the flushing drain
valve using appropriate customer supplied fittings. Us-
ing the drain helps to promote superior flushing and
draining results.
SP10 Priming Time Chart
1” (25.4 mm) Suction Piping
1.5” (38.1 mm) Suction Piping
Impeller
Diameter
Motor Speed
Motor Speed
3450 RPM
2900 RPM
3450 RPM
2900 RPM
Feet of Lift (sec.)
Meters of Lift (sec.)
Feet of Lift (sec.)
Meters of Lift (sec.)
in. (mm)
5
10
15
20
25
1.5
3.1
4.6
6.1
7.6
5
10
15
20
25
1.5
3.1
4.6
6.1
7.6
4.18 (106.2)
10
35
65
100
140
10
40
80
160 240
25
60
100
150
210
30
75
145
255
455
4.00 (101.6)
12
37
68
130
310
20
50
90
200 320
28
60
100
180
280
35
80
150
360
3.75 (95.3)
15
45
72
155
30
45
135
30
70
110
275
40
95
240
3.5 (88.9)
20
50
75
185
35
75
225
35
80
150
60
120
3.25 (82.6)
25
60
145
37
150
40
88
240
85
225
3 (76.2)
27
115
60
55
165
120
NOTE: Times shown are guidelines only. Times will vary based on system and piping setups.