ii. Intalogix™ Technology Interface (QMB 15291):
QMB
Intalogix™
Terminal
Wire Color
Function
Technology Inst
1
Green
(-) Excitation
1
2
Red
(+) Excitation
2
3
Black
Ground
3
4
White
D out
4
5
Brown
D In
5
6
Blue
EOC
6
7
Orange
SCLK
7
8
Yellow
CS
8
9
Violet
Temperature
9
10
Gray/Shield
Chassis
10
7. Adjust the analog indicator to the platform. First, ensure all corners are within one
division of each other at 25% of the rated capacity specification. Follow the
calibration procedure in the appropriate indicator service manual to ensure a good
calibration.
a. Perform a coarse platform calibration approximate to the actual weight.
b. Identify the platform corner numbers.
51103
9
01/07 -- Rev. 1
Top View
50604-1
2
3
4
1
NOTE: 1. If the Gray/Shield wire is equipped with a screw lug, it can be attached using
one of the PCB screws.
2. Calibrate the Intalogix™ platform / indicator. Follow the calibration procedure in
the appropriate indicator service manual.