beautypg.com

Fairbanks Aegis Industrial Stainless User Manual

Page 9

background image

ii. Intalogix™ Technology Interface (QMB 15291):

QMB

Intalogix™

Terminal

Wire Color

Function

Technology Inst

1

Green

(-) Excitation

1

2

Red

(+) Excitation

2

3

Black

Ground

3

4

White

D out

4

5

Brown

D In

5

6

Blue

EOC

6

7

Orange

SCLK

7

8

Yellow

CS

8

9

Violet

Temperature

9

10

Gray/Shield

Chassis

10

7. Adjust the analog indicator to the platform. First, ensure all corners are within one

division of each other at 25% of the rated capacity specification. Follow the

calibration procedure in the appropriate indicator service manual to ensure a good

calibration.

a. Perform a coarse platform calibration approximate to the actual weight.

b. Identify the platform corner numbers.

51103

9

01/07 -- Rev. 1

Top View

50604-1

2

3

4

1

NOTE: 1. If the Gray/Shield wire is equipped with a screw lug, it can be attached using

one of the PCB screws.

2. Calibrate the Intalogix™ platform / indicator. Follow the calibration procedure in

the appropriate indicator service manual.