Mounting Procedure:

1. Find a convenient location between the Fuel Servo and Flow

Divider and away from any hot exhaust pipes to suspend the
Fuel Flow Transducer. The Transducer must mounted within
6" of a hose support or fitting. The support or fitting may be
on the input or output line of the Flow Transducer and the
support may be to an adjacent hose.

2. Remove the fuel hose which goes from the Fuel Servo to the

Flow Divider.

3. Purchase two new hoses: one to be used from the Fuel Servo

to the Fuel Flow Transducer and the other to be used from the
Fuel Flow Transducer to the Flow Divider.

There must be

flexible hose in and out of the Fuel Transducer. The hoses
must meet TSO-C53a Type C or D FAA specifications.

The

new hoses must be the same size as the current hoses in
the aircraft. Sources of fittings and fabricated hoses are:

Adapter, (1/4" NPT
to Fuel Hose)

(IN)

(OUT)

From the Fuel Servo

To the Flow Divider

Sacramento Sky Ranch Inc.

(916) 421-7672

Fax: (916) 421-5719

Varga Enterprises Inc.

(602) 963-6936

FAX: (602) 899-0324

O R

O R

O R

O R

O R

O R

O R

O R

O R

O R

Hoses Unlimited Inc.

(510) 483-8521

Fax: (510) 483-8524

4/15/94

R. R.

R.R.

None

Installation of the Fuel Flow Transducer suspended in the fuel
line between the Fuel Servo and the Flow Divider.

Note: Only applicable for installation on aircraft with a fuel

return line from the Fuel Servo.

0415941

0415941

0415941

0415941

0415941

B: 7/2/02

Drawn By:

Approved By:

Scale:

Material:

Next Assembly:

P/N:

Date:

Rev:

D/N:

Electronics International Inc.

Electronics International Inc.

Electronics International Inc.

Electronics International Inc.

Electronics International Inc.

4. Mount the Fuel Flow Transducer in the fuel line.

You must use the FT-90 (Gold Cube) Fuel Flow Trans-

ducer on any engine over 350 H.P. If the Transducer is mounted within 6" of an exhaust pipe, the
Flow Transducer must be wrapped with Fire Sleeving.

5. Read the Installation Instructions for important installation considerations.