Model No. TD-8580A

Safety

3

Safety

CAUTION: The cube can reach 100 °C (212 °F). Do not touch the cube while
the apparatus is in use. Allow the apparatus to cool completely after use before

handling. Do not apply more than 10 V to the apparatus. Always monitor the temper-
ature when the apparatus is in use. Do not allow the cube to exceed 100 °C. This
apparatus is intended for use by students only under instructor supervision.

Suggested Experiments

The configuration files called for in these activities can be found on the included
CD-ROM. There are three folders, each containing different versions of the files.
Refer to the table below to find the appropriate files for your equipment.

1. Infrared Light Intensity versus Temperature

In this experiment you will measure the IR intensity emitted by the cube as its temper-
ature increases.

Setup

1. Mount the Thermal Cavity on the included base. Connect the Thermal Cavity to

the Thermistor Sensor and power supply (but don’t turn it on yet).

2. Connect both sensors to the interface (or interfaces).

1

3. Position the IR sensor on a stand or book so that its sensitive element is 2 cm

from the black surface of the cube.

Equipment

Folder containing configuration files

PASPORT

PASPORT

ScienceWorkshop (without Power Amplifier)

ScienceWorkshop

ScienceWorkshop with Power Amplifier

SW with Power Amp

Required Equipment

Thermal Cavity

TD-8580A

For use with PASPORT

Infrared Sensor

PS-2148

Temperature Sensor

PS-2125 or similar

1

1

Any PASPORT temperature sensor compatible with thermistor temperature probes can be

used, including the Xplorer GLX’s built-in temperature port.

PASPORT interface or interfaces

2

2

A multiple-port interface or combination of two single-port interfaces is required.

See PASCO catalog or www.pasco.com

Power Supply, 10 V, 1 A

PI-9877, SE- 9720a, SF-9584A, or similar

For use with ScienceWorkshop

Infrared Sensor

CI-6628

Thermistor Sensor (10 k

)

CI-6527A

ScienceWorkshop Interface

See PASCO catalog or www.pasco.com

Power Amplifier

3

or

Power Supply, 10 V, 1 A

3

The Power Amplifier requires a ScienceWorkshop 750 or 700 interface.

CI-6552A

PI-9877, SE- 9720a, SF-9584A, or similar

1

If you are using a

ScienceWorkshop inter-
face, connect the IR sen-
sor to Channel A and the
Thermistor sensor to
Channel B; connect the
Power Amplifier (if used)
to Channel C; set the
gain of the IR Sensor
to 1.