1601-265-C-6-11
DoorKing Part Number
1601-310
Copyright 2011 DoorKing, Inc. All rights reserved.
Cable Eyelet MUST be installed in turnbuckle.
Cable Clamp
Important: Do not adjust cable too tight or it will bind.
Install eye bolt into arm
hinge with vise-grips.
Attach arm hinge to arm
with 4 self-tapping
screws.
1
2
3A
3A
Adjusting and Locking Cable Assembly
Existing Stud
After adjusting cable tension, lock turnbuckle
with nuts to keep turnbuckle from twisting.
Allow turnbuckle to
loosen or tighten.
Install arm on hub.
3
4
Install cable. Cable MUST clear hub!
Rotate arm up and down. Adjust cable tension with turnbuckle
to level outer arm. Make sure that cable assembly is not binding
or twisting and everything moves freely.
Cut off excess cable.
Top View of
Operator Housing
Side View of
Operator Housing
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Hub
Remove stud from operator housing
and assemble as shown.
Lock eye bolt with nut to keep eye bolt from twisting.
Bushing
Operator Housing
Adjust to clear hub.
Pre-Crimped Eyelet
Inner Arm
Outer Arm
Bolt Head (Inside Housing)
Washer (Inside Housing)
Locknut
Install second arm
with 4 self-tapping
screws.
Installing Arms