Danger – DoorKing 1602 Barrier Gate User Manual
Page 14
1601 Manual Release Kit
Installation
Wiring Interlock
DoorKing Part Number
1601-270
This kit is designed for the 1601 barrier gate operator WITHOUT the convenience open option. It provides an interlock power cut-off
switch when manually using crank tool to move the arm up or down. DO NOT install on convenience open models.
Replace the existing AC power switch wire connected to
terminal #2 with interlock cut-off switch wires.
Replace existing
single motor
pulley with double
motor pulley.
Align motor pulley
with gear reducer
pulley.
Mount interlock
assembly using
existing hardware.
Mount spring clips
with lock nuts on
existing threaded
studs inside
access door.
Shut off the AC input
power to the operator
from the circuit
breaker.
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Kit Includes:
Pre-wired Interlock assembly,
Double motor pulley, Crank tool,
2 spring clips with lock nuts.
NC NO
1
2
3 4 5 6 7 8 9 10 11 12 13 14
DANGER
HIGH VOLTAGE!
AC Power
Switch
Interlock
Cut-Off
Switch
Existing 115 VAC
Power Terminal Wire
Crank T
ool
Storage
Use existing
wire restrainers
to run wires.
Keep wires clear
of all moving parts
Interlock Assembly
Gear
Reduce