Model 1601 fan kit installation, Shut off all power to operator, Danger – DoorKing 1602 Barrier Gate User Manual
Page 5
MODEL 1601 FAN KIT
Installation
1601-093-B-5-11
DoorKing Part Number
1601-093
Copyright 2011 DoorKing, Inc. All rights reserved.
This kit is designed for the 1600 model barrier gate operators only. Recommended for hot and humid climates. An automatic
thermostat will control heat and humidity inside operator housing.
Kit Includes:
Fan Assembly with black and white wires, 5 wire ties,
3 double stick wire tie mounts, 2 plastic wire restrainers and 3 nylon
lock nuts.
Connect the fan power
wires according to
operator model type.
Mount fan using 3 existing
threaded studs and lock
nuts supplied. Slide
mounting tabs over
existing air duct.
Keep intake vents clear of debris.
Air
Flow
2
4
Fan switch settings.
OFF
- Turns the fan off.
ON
- Turns the fan on continuously.
AUTO
- Normal setting. Automatically turns the fan ON when the
temperature rises above 90°F inside the housing, and turns the fan OFF
when the temperature drops below 90°F.
5
Intake V
ents
Wire Stays
Exist
ing
Air Duct
Existing
Air Duct
Existing Wire Restrainers
Neutral
Neutral
Neutral
Mounting
Tab
Mounting
Tab
Hot
115 V
AC Hot
115 VAC Models
230 VAC/460 VAC Models
DANGER
HIGH VOLTAGE!
1
2
1
2
3
4
5
Exhaust V
ents
Lock Nut
Lock Nut
Lock
Nut
Threaded
Housing Studs
(Existing)
Threaded
Air Duct
Stud
(Existing)
Route fan wires as shown. Use supplied
wire stays and existing wire restrainers.
Keep wires clear of all moving parts.
3
3
1
2
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
4
Shut off ALL power to operator
Turn off the DC convenience open power switch
on certain operator models FIRST then shut off
the AC input power to the operator from the
circuit breaker.