beautypg.com

Adjusting and locking cable assembly, Operator h ousing, Installing arms – DoorKing 1602 Barrier Gate User Manual

Page 2

background image

1601-083-C-5-08

DoorKing Part Number

1601-083

Copyright 2008 DoorKing, Inc. All rights reserved.

Top View of

Operator Housing

Side View of

Operator Housing

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

Hub

Existing Stud

Important: Do not adjust cable too tight or it will bind.

Adjusting and Locking Cable Assembly

After adjusting cable tension, lock turnbuckle
with nuts to keep turnbuckle from twisting.

Rotate arm up and down. Adjust cable tension with turnbuckle
to level outer arm. Make sure that cable assembly is not binding
or twisting and everything moves freely.

Lock eye bolt with nut to keep eye bolt from twisting.

Inner Arm

Outer Arm

Cable Eyelet MUST be installed in turnbuckle.

Cable Clamp

Install eye bolt into arm
hinge with vise-grips.
Attach arm hinge to
inner arm with 4
self-tapping screws.

1

2

3A

3A

Allow turnbuckle to
loosen or tighten.

Install inner arm
on hub.

3

4

Install cable. Cable MUST clear hub!

Cut off excess cable.

Remove stud from operator housing
and assemble as shown.

Bushing

Operator H

ousing

Adj

ust to clear

hub.

Pre-Crimped Eyelet

Bolt Head (Inside Housing)

Washer (Inside Housing)

Locknut

Install outer arm
with 4 self-tapping
screws.