Installation of heater, Mount heater, Route heater wires as shown – DoorKing 1602 Barrier Gate User Manual
Page 7: Shut off all power to operator, Power connection heater switch, Danger
Installation of Heater
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
1601-164-G-7-11
DoorKing Part Number
1601-092
Copyright 2011 DoorKing, Inc. All rights reserved.
Kit Includes:
Heater / mounting plate, 2 locknuts, 5 wire ties, 3 double stick wire tie mounts, and 2 plastic wire restrainers.
Connect the heater power wires according to operator
AC power type.
4
DANGER
HIGH VOLTAGE!
Mount Heater
Locate existing threaded studs in
operator. Heater MUST be
mounted on mounting plate.
Place the 2 supplied
washers between the
operator wall and
the mounting plate to create
an air gap.
2
AUTO
- Normal setting. Automatically turns the heater ON when the
temperature drops below 40°F inside the operator, and turns the heater
OFF when the temperature rises above 40°F inside the operator.
OFF
- Turns the heater off.
ON
- Turns the heater on continuously. The heater will become VERY
HOT when running continuously.
5
Wire Stays
Existing Wire Restrainers
Neutral
Neutral
Hot
Air Gap
115 V
AC Hot
115 VAC Models
230 VAC/460 VAC Models
1
Washer
Locknut
Locknut
Washer
2
1
2
3
4
5
Route heater wires as shown.
Use supplied wire stays and existing wire
restrainers.
CAUTION:
Heat will be
transferred to the outside
wall of the operator if NO
air gap exists between the
heater and the inside wall
of the operator.
DANGER
HOT!
4
Shut off ALL power to operator.
Turn off the DC convenience open power switch on
certain operator models first then shut off the AC input
power to the operator from the circuit breaker.
1
3
Power Connection
Heater Switch
Mounting
Plate
Operator
Threaded
Stud
(Existing)
Operator
Threaded
Stud
(Existing)
Keep wires clear of all moving parts
and the heater vents.
2
5