DESCRIPTION
These magnetic disc brakes mount directly onto NEMA
56C, 143TC, and 145TC frame motors, on the end
opposite the drive shaft. The brake is direct acting,
electro-magnetically released, and spring set. It uses
rotating friction and stationary disc contact to supply
positive braking action. It retains quick release and
setting capabilities at all times.
WARNING: Do not install or use these brakes in an
explosive atmosphere.
Figure 1
4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsco.com
Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself
and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain instructions for future reference.
Inertia of
Dimensions
Number of
*Thermal
Rotating
Model
Rotating Torque
Capacity
Parts
X
G
AC
C
N
+ 1/32
Number
Discs
Lb-ft
HPS/MIN. Lb. Ft.
2
2-61001-524 1
1.5
6
.006
.875
1.19
.585
4.13
1.125
2-61003-524 1
3
6
.006
.875
1.19
.585
4.13
1.125
2-62006-524 2
6
6
.010
.875
1.19
.585
4.13
1.125
2-62010-524 2
10
6
.010
.875
1.19
.585
4.13
1.125
2-63015-524 3
15
6
.015
1.187
1.56
.873
4.50
1.437
2-63020-524 3
20
6
.015
1.187
1.56
.873
4.50
1.437
2-64025-524 4
25
6
.020
1.344
2.25
1.562
5.19
2.000
*Thermal capacity (HPS/MIN.) was determined under the following test conditions: a) Room temperature 72
o
F. b) Stopping time of one second or less.
c) Brake mounted in a horizontal position. d) Equal on and off times. e) 1800 RPM f) Coil energized with 110% of rated voltage.
G060871-001