The diamond wire
SB Wire Sawing System
Page 24
SB_0107_e.mif
7KH GLDPRQG ZLUH
,QWURGXFWLRQ
These operating instructions describe 2 con-
necting elements for 2 different types of wire.
:LUH W\SHV
We distinguish between sintered wire of 11
mm diameter and electro-plated wire. (See
page 27) SB_0107_e.fm.
l
Only use the original TYROLIT connectors
for assembly and the original TYROLIT
tools, which are provided, for the fitting of
these connectors
l
Never kink the wire!
l
If the wall thickness is less than 80 cm oper-
ate with reduced pressure to limit the wear
on the beads
&RQQHFWLQJ HOHPHQWV
Both wires can be connected or repaired with
the following connecting elements:
- Repair sleeve
- Knuckle connection
6WRUDJH RI ZLUH
l
After use clean the wire and always make
sure it is stored dry and protected from the
light
The screw connection should not be used
with the SB!