Electrical Requirements and Wiring Diagrams

All field installed wiring to the unit heater must be done in accordance with national, state, provincial,
local codes and to the guidelines in this manual. In the United States, refer to the most current revisions
to the Electrical Code ANSI/NFPA 70 and in Canada refer to the most current revisions to the Canadian
Electrical Code CSA C22.1 Part 1. The unit must be electrically grounded according to these codes.
Line polarity must be observed when making field connections.

Internal Wiring Diagrams

Before wiring this appliance, check the existing wiring; replace if necessary. If any of the original wire
supplied with the appliance must be replaced, it must be replaced with copper wiring material having a
rating of at least 600V, 105°C.

Figure 3.2

Internal Wiring Diagram

WARNING

!

Shock hazard. Disconnect power supply before making wiring connections to prevent
electrical shock and equipment damage.

Any original factory wiring that requires replacement must be replaced with wiring

material having a temperature rating of at least 105°C.