Troubleshooting Guide

Were the gas lines

purged of all air?

Does the heater’s gas

type match the gas

supplied?

Yes

Check manifold pressure. Are

you reading within the specified

pressures per the rating plate?

Yes

Purge gas lines.

No

Contact local

representative or factory.

No

Adjust pressure or

replace gas valve.

No

Check circuit board

for flash codes.

Consult factory.

Yes

Is the heater properly

grounded? Is the

heater’s polarity

correct?

Correct grounding or

fix polarity.

No

With a micro ammeter,

check micro-Amp reading

of flame sensor circuit. Is

it greater than 0.5 micro-

Amps?

NOTE: Meter must

be connected in

series.

Yes

Yes

No

Check circuit board flash

codes. Replace ignition

module.

Replace circuit board.

United Technologies Circuit Board

LED CODE

(# of flashes)

GREEN LED STATUS / ERROR

STEADY OFF

Internal Control Fault or No Power

STEADY ON

Control Ok

1

In Lockout from Failed Ignitions or Flame Losses

2

Pressure Switch Open with Inducer ON

3

Pressure Switch Closed with Inducer OFF

4

Limit Switch is OPEN

5

In Lockout from False Flame

LED CODE

(# of flashes)

AMBER LED STATUS / ERROR

FAST FLASH

Flame Present With Gas Valve Off

STEADY ON

Flame is Sensed

Fenwal Circuit Board

LED CODE

(# of flashes)

GREEN LED STATUS / ERROR

SLOW FLASH

Normal Operation - No Call for Heat

FAST FLASH

Normal Operation - Call for Heat

2

Ignition Lockout - No Flame Detected

3

Airflow Fault - Pressure Switch Open or Closed

4

High Limit or Rollout Switch Open

5

Flame Sense Error - Gas Valve Not Energized

STEADY ON

Internal Control Failure

LED CODE

(# of flashes)

AMBER LED STATUS / ERROR

OFF

Flame Signal is Below Required Level / No Flame Present

STEADY ON

Flame is Sensed

LED Diagnostic Codes