TROUBLESHOOTING

If problems develop, use the chart below to service the pump.

4

FORM 3069A (05-04)

Pump will not start

Poor pump performance

No hydraulic flow and pressure

Hydraulic motor

Couplers

Hydraulic connection

Hydraulic oil flow is low

Pump is too deep in sediment

Pump intake is plugged

Discharge hose is twisted or kinked

Discharge hose is too small

Lift is too high for power supply

Pump not sufficient for application

Damaged or worn impeller

Turn power on. Check to make sure
the oil flow range (5-9gpm /
8-14gpm), and 2000psi oil pressure are
ok.

Repair or replace as needed.

Check to make sure the couplers are
completely connected and not defective.
If defective, replace.

Connected backwards. Reinstall in
proper direction.

Turn power on. Check to make sure
the oil flow range (5-9gpm /
8-14gpm), and 2000psi oil pressure are
ok.

Place pump on solid support.

Make sure debris has not wrapped
around base of pump.

Make sure the hose is straight.

Make sure hoses are 2” dia. Model 20,
and 2-1.2” dia. Model 25.

Maximum lift is 70ft Model20, and 95 ft.
Model 25.

Make sure pump specs are sufficient for
application.

Replace as required.