beautypg.com

Reassembly – MP Pumps PETROLEUM SELF-PRIMING 30, 40 INSTRUCTION User Manual

Page 3

background image

This pump is equipped with a self-lubricated

the seal.

shaft seal. The self-lubricated seal is
lubricated by the liquid in the pump.

If the pump is to be left standing idle for any
length of time in freezing conditions, the pump
housing should be drained. Draining is provided
for by a plug at the base of the pump housing.

Foreign matter between sealing faces will
cause leakage and shorten life of the seal.

TO REMOVE PUMP HOUSING

MOUNTING PUMP HOUSING

Remove capscrews and nuts holding pump
housing to base (where used).

Replace gaskets on pump housing and
mount housing on the adapter. Replace two

Remove nuts and lock washers holding pump

lock washers and nuts on studs diagonally

housing to adapter.

across from each other and tighten. Turn
drive shaft over slowly by hand and listen

Loosen the housing and remove carefully to

at housing outlet opening for any impeller

prevent tearing gaskets.

rubbing on the housing or wear plate.

The clearance between the impeller and
wear plate can be checked with a feeler
gauge. Normal clearance is .015" to .025".

MOUNTING ADAPTER

If clearance exceeds .025" readjust impeller.
If the impeller rubs use an additional gasket

Before mounting adapter, clean counterbore

to space impeller.

thoroughly.

After clearance has been established,

Clean and lubricate the synthetic member on

replace lock washers and nuts on remaining

seal seat and press (do not drive) the assembly

studs and tighten. If capscrew and nuts are

into the adapter counterbore, seating it firmly and

used to hold housing to mounting base,

squarely against the shoulder being sure that the

replace these and tighten.

polished side is facing up.

In handling, avoid dropping seat and take particular care
not to scratch the lapped face.

Press the seal assembly on to the drive sleeve
using a water-soluble lubricant to aid in pressing
the seal assembly.

IMPORTANT

The assembly of impeller and seal to the drive
shaft should take place as soon as the bellows
assembly is slipped on the impeller sleeve so as
to avoid bonding of the bellows to the sleeve at
the impeller working working height.

CAUTION

Operating the pump dry will seriously damage

REASSEMBLY

PRINTED IN THE U.S.A.

FORM 3075-A (6/08)

CAUTION