beautypg.com

Mallory Ignition Mallory HYFIRE V ELECTRONIC IGNITION CONTROL 585 User Manual

Page 5

background image

5

MALLORY TECHNICAL SUPPORT

(775) 882-6600

[email protected]

CHECKING FOR SPARK
If triggering the ignition with the white wire:
(See Figure 6)
1. Make sure the ignition switch is in the “OFF” position.
2. Remove the coil wire from the distributor cap and set the terminal

approximately 1/4" from engine ground, such as the intake manifold.

3. Disconnect the HYFIRE

®

V Ignition Control white wire from the

distributor’s points or ignition amplifier.

4. Turn the ignition to the “ON” position. Do not crank the engine.
5. Tap the white wire to ground several times. Each time you pull the

wire from ground, a spark should jump from the coil wire to ground.

If spark is present, the ignition is working properly. If there is no

spark, skip to Step 6 below.

If Triggering With the Magnetic Pickup:
(See Figure 7)
1. Make sure the ignition switch is in the OFF position.
2. Remove the coil wire from the distributor cap and set the terminal

approximately 1/4" from engine ground, such as the intake manifold.

The illustrations on the following pages show the

best way to install the HYFIRE

®

V Ignition Control

on various applications. If you have any problems

or questions while installing this device on your

vehicle, contact the Mallory Technical Service

Department at (775) 882-6600, 8:00 AM to 5:00 PM

Pacific time, or email [email protected].

3. Disconnect the HYFIRE

®

V Ignition Control magnetic pickup wires

from the distributor.

4. Turn the ignition to the ON position. Do not crank the engine.
5. With a small jumper wire, short the HYFIRE

®

V Ignition Control

green and violet magnetic pickup wires together. Each time you

break this short, a spark should jump from the coil wire to ground.

If spark is present, the ignition is working properly. If there is no

spark skip to Step 6 below.

6. If there is no spark.

A. Inspect all of the wiring.
B. Substitute another coil and repeat the test. If there is now spark,

the coil is at fault.

C. If there is still no spark, check to make sure there is 12 volts on

the small red wire from the HYFIRE

®

V Ignition Control when

the key is in the ON position. If 12 volts is not present, find

another switched 12 volts source and repeat the test.

D. If, after following the test procedures and inspecting all of the

wiring, there is still no spark, the HYFIRE

®

V Ignition Control is

probably in need of repair. See the Warranty and Service sec-

tion for information.

TO GROUND

WHITE

WIRE

FIGURE 6

JUMPER WIRE

GREEN

VIOLET

FIGURE 7