OPERATIONS MANUAL

UPMS-1000-XXX

MAGNUM VENUS PLASTECH

REV 1.02

NOVEMBER 2010

PAGE 20


TOTAL A


Cycle display using the MODE button, until the

TOTAL A

is displayed.


Press and hold the ENT button until the display enters program mode. At this point you should see

KFT

A VALUE

, with a number underneath it. The first digit should be blinking.


Press SEL until the decimal point is blinking. Using the UP or DN button, move the decimal until 3

decimal places are set. Then, using the SEL and UP and DN buttons, set the

KFT A VALUE

to the

appropriate value. At this point .500 should be used. The KFT A VALUE will be set in the Calibration
section.

Press ENT

to accept

KFT A VALUE

setting. This will then move to the next screen.


Set the

ENG UNITS A

display by using the UP or DN and SEL buttons. Either set to KG, GR, LBS or

OZ.

Note: Remember what measurement was setup to display. This is the measurement that needs to be used
during the calibration process.


Press ENT

to accept

ENG UNITS A

setting. This will return you to the

TOTAL A

display.



TOTAL B

Cycle display using the MODE button, until the

TOTAL B

is displayed.


Press and hold the ENT button until the display enters program mode. At this point you should see

KFT

B VALUE

, with a number underneath it. The first digit should be blinking.


Press SEL until the decimal point is blinking. Using the UP or DN button, move the decimal until 3
decimal places are set. Then, using the SEL and UP and DN buttons, set the

KFT B VALUE

to the

appropriate value. At this point .500 should be used. The

KFT A VALUE

will be set in the Calibration

section.

Press ENT to accept

KFT B VALUE

setting. This will then move to the next screen.


Set the

ENG UNITS B

display by using the UP or DN and SEL buttons. Either set to KG, GR, LBS or

OZ.

Note: Remember what measurement was setup to display. This is the measurement that needs to be used
during the calibration process.

Press ENT to accept

ENG UNITS B

setting. This will return you to the

TOTAL A

display.