OPERATIONS MANUAL

UPMS-1000-XXX

MAGNUM VENUS PLASTECH

REV 1.02

NOVEMBER 2010

PAGE 19

DISPLAY PROGRAMMING

(cont)

TOTAL A B

No programming necessary.

STATUS ONE

No programming necessary.

WARNINGS

Although you can program alarms from here it is recommended that the alarms be programmed
from the

RATIO A B

setup.


RATE A

Cycle display using the MODE button, until the

RATE A

is displayed.

Press SEL until the decimal point is blinking. Using the UP or DN button, move the decimal until

3 decimal places are set. Then, using the SEL and UP and DN buttons, set the

KFR A

VALUE

to the appropriate value. At this point .500 should be used.

The KFR A VALUE

will

be set in the Calibration section.

Press ENT

to accept

KFR A VALUE

setting. This will then move to the next screen.

Press ENT

to accept

SAMPLE A

setting (Leave at 10). This will then move to the next screen.

Set the

ENG UNITS A

display by using the UP or DN and SEL buttons. Either set to KG/M,

GR/M, LBS/M or OZ/M

Note: Remember what measurement was setup to display. This is the measurement that needs to be used
during the calibration process.

Press ENT

to accept

ENG UNITS A

setting. This will return you to the

RATE A

display

RATE B

Cycle display using the MODE button, until the

RATE B

is displayed.

Press SEL until the decimal point is blinking. Using the UP or DN button, move the decimal until
3 decimal places are set. Then, using the SEL and UP and DN buttons, set the

KFR B

VALUE

to the appropriate value. At this point .500 should be used.

The KFR B VALUE

will

be set in the Calibration section.

Press ENT

to accept

KFR B VALUE

setting. This will then move to the next screen.

Press ENT

to accept

SAMPLE B

setting (Leave at 10). This will then move to the next screen.

Set the

ENG UNITS B

display by using the UP or DN and SEL buttons. Either set to KG/M,

GR/M, LBS/M or OZ/M

Note: Remember what measurement was setup to display. This is the measurement that needs to be used
during the calibration process.

Press ENT

to accept

ENG UNITS B

setting. This will return you to the

RATE B

display