CHAPTER 3-General Setup
DISPLAY SETUP
1. Cycle display using the MODE button, until the main logo is displayed.
2. Press and hold the ENT button until the display enters program mode. At this point you should
see DISPLAY 00 with LOGO underneath. What this means is that the 00 display will show the
LOGO screen. DISPLAY 00 should always be programmed to the LOGO setting.
3. Once in program mode pressing the DN button will turn the display OFF/ON. Pressing the SEL
button will cycle through the available displays.
4. Once you have chosen a readout for the display location Press ENT button again. This will set
the current selection to memory and increment to the next display for programming.
5. Repeat step 3 until all the displays are programmed to the initial matrix below.
The following displays are always on.
DISPLAY 00
LOGO
DISPLAY 01
RATIO A B
DISPLAY 02
TOTAL A B
DISPLAY 03
STATUS ONE
DISPLAY 04
WARNINGS
The next set of displays must be on for calibration of the UPMS-1000 to the metering pump. They can
be left on or turned off after calibration. Customer preference.
DISPLAY 05
RATE A
DISPLAY 06
RATE B
DISPLAY 07
TOTAL A
DISPLAY 08
TOTAL B
DISPLAY 09-19
OFF
There are multiple displays available for viewing. The FEM-03 will display 19 readings at a time.
Consult the FEM-03 manual and the customer to decide which additional displays need to be
programmed.