H.I.S. Troubleshooting Manual
CHAPTER 1
CAUTION!!
Before attempting to disassemble any portion of catalyst or resin
system:
1. The air supply to power head of pump should be turned off.
2. The fluid pressure in the system should be relieved by triggering gun and
allowing fluid to drain into proper receptacle.
3. The air charge on both resin and catalyst accumulators should be released
through charging valves on top of accumulators.
4. Air to solvent tank should be turned off and the pressure relieved from tank.
(Only after flushing gun clean of all resin and catalyst.)
5. If pressure is trapped in system by a fluid block, plugged filter, set-up gun,
etc., remove pressure by disconnecting resin line prior to suspected
blockage.
Note: A large rag or shop towel should be held tightly around wrench and
fitting as fitting is removed. Remove fitting slowly allowing fluid pressure
to escape into rag or towel.
CHAPTER 2:
STOP!!!
Before attempting to perform maintenance on the Magnum Venus System:
1. Protective clothing should be worn at all times.
2. Safety glasses should be worn at all times.
3. Maintenance should not be performed unless others are in attendance to render
assistance in case of an emergency.
4. Should any parts of the body come in contact with MEKP, the area should be
washed immediately with large amounts of clean water.