Mini Link Operations Manual
Rev. 08/2013
Page | 26
Start-Up & Shut-Down:
DAILY SHUT-DOWN:
1.
For shut-down, the fluid pump shafts should be in the bottom of the stroke to
avoid any material from drying on the shafts. Not following this procedure will
have a great effect on piston rod seal life. Set the Select switch to Recirc.
Turn the Start / Stop switch to Stop just before the pumps reach the bottom
reversal.
2.
Flush both A & B side of the mix chamber into a waste container and air purge
dry.
3.
Remove mixer from mix housing. Inspect the static mixer that it has been
completely cleaned of metered materials.
4.
Remove Mix housing, spring and balls and inspect for any set-up materials.
Depending on the resin systems used it may not be necessary to remove mix
housing for shut-down every day however the static mixer should always be
removed for daily shut-down.
5.
Turn the electrical Power switch to Off
6.
Turn off the Main Air Inlet valve
7.
Remove the flush tank pressure by lifting the relief valve ring.
8.
Open the fluid Pressure Relief valves on the material manifolds to release fluid
pressure and then close.