beautypg.com

Liquid Controls IT300N-BBL User Manual

Page 5

background image

4

DEFINITIONS

ent Code

: (enter code) This prompt will only appear if the panel lock is ON. Press the

key to

increment each digit. Press the

key to step to the next digit to the left. Press the E key to

enter the 4 digit code. If the entered code is correct, the display will advance to the next
menu prompt (CLr tot). If incorrect, the display will return to the run mode.

Clr tot

: (clear total) Clears (resets) the totalizer. Press the E key to clear the total and return to

the run mode. Press the M key to skip and advance to the next menu selection.

FAC nnUl

: (factor multiplier) Sets the factor multiplier value. Press the

key to select

1

,

10

,

100

,

1000

. Press the E key to enter the displayed value.

fdeC

: (factor decimal) Sets the decimal location for the factor. This location is restricted to 3

places (59.999). The use of this decimal automatically limits the number of decimal locations
allowable in the rate and total to acceptable ranges. Press the

key to move the decimal.

Press the E key to select the displayed decimal location.

faC

lInear

/

10poInt

: (factor type) This prompt will only appear if the unit is ordered with the 10 point

linearization option. The

10 poInt

linearization selection is recommended for flow meters

whose K-factors change with different flow rates. This selection allows users to enter up to
10 different frequencies with 10 corresponding K-factors for different flow rates. The

lInear

setting is used for flow meters whose output is linear over its' entire operating flow range.
Press the

key to step to the desired choice. Press the E key to enter the displayed factor

type.

No

/

yes

set10pt

: (set 10 point?) This prompt allows the user to skip the 10 point setup routine.

Select

yes

for initial setup or to change the present 10 point values. Select

No

to skip and

keep the existing values.

faC

: (factor) This prompt appears on all units with linear inputs. The Factor is the number of

pulses per unit volume for the flow sensor. The pulses/unit volume is implied by the totalizer
descriptor when a descriptor is used. The implied units for the Factor are then as follows:

GAL

pulses/gallon

LIT

pulses/liter

FT3

pulses/ft3

M3

pulses/M3

Factors from 0.001 to 59999 may be used. A 0 value for the factor is not allowed and a
warning message will be given. The factor is displayed on the subsidiary (lower) display.
Press the

key to increment each digit. Press the

key to step to the next digit to the left.

Press the E key to enter the displayed factor.