beautypg.com

Battery life expectancy, Specifications, Run time part number – Liquid Controls IT300N-BBL User Manual

Page 2

background image

1

SPECIFICATIONS

Description
Featuring 4

1/2

digits of rate and 8 digits of total, the IT 300N is a

battery powered indicator capable of accepting magnetic
pickup, DC pulse and switch closure inputs. The unit provides a
loop powered 4-20mA output. The IT 300N uses the 4-20mA
loop to provide power when this output is used.

Specifications
POWER:
BATTERY POWERED

Supplied with 2 C size Lithium battery pack.

EXTERNAL POWER INPUT

Voltage: 8.5 to 30 VDC
Current: Less than 5 mA
Protection: Reverse Polarity Protection on DC Power Input

LOOP POWERED

Voltage: 8.5 to 30 VDC
Protection: Reverse Polarity Protection on Current Loop
Loop Burden: 8.5V maximum

DISPLAY:
Rate Display: (selectable decimal)

4.5 Digits (59999), 0.35" High, Display updates once every
two seconds
Rate Descriptors: /SEC, /MIN, /HR
Min. Input Frequency: 5 Hz (delay of 0.2 seconds)

Totalizer Display: (selectable decimal)

8 Digits (99999999), 0.2" High
Totalizer Descriptors: GAL, LIT, FT3, M3, "blank"

Warning Displays: Low battery warning

PULSE OUTPUT:

The pulse output advances with the least significant digit of
the totalizer or decimal multiples there of (see Pulse output
divider).
Type: Isolated photomos relay
Max. voltage (off state): 30 VDC
Current (on state): 100mA
Pulse Duration: Selectable (see below)
Pulse Output Rate: Selectable (see below)

SPEED (HZ)

1

2

4

8

Min. on/off (msec)

500

250

125

62.5

Pulse output divider: User selectable,

ч

1,

ч

10,

ч

100 or OFF

NOTE:

Select OFF for max. battery life.

ACCURACY:

0.01% Reading,

±

1 count

Temperature Drift: 50 ppm/

°

C Worst Case

ENVIRONMENTAL:

-22

°

F (-30

°

C) to + 158

°

F (70

°

C)

HUMIDITY

0 - 90% Noncondensing

INPUTS:
MAGNETIC PICKUP INPUT

Frequency Range: 0 to 3500 Hz
Trigger Sensitivity: 30 mV p-p
Over Voltage Protected:

±

30 VDC

OPTO-ISOLATED DC PULSE INPUT

High (logic 1): 4-30 VDC
Low (logic 0): Less Than 1 VDC
Minimum Current: .5 mA
Hysteresis: 0.4 VDC
Frequency Range: 0 to 5 kHz
Min. Pulse Width: 0.1 msec

CONTACT CLOSURE INPUT (contact closure to common)

Internal Pullup Resistor: 100 K

to +3.6 VDC

High (logic 1): Open or 4-30 VDC
Low (logic 0): Less Than .5 VDC
Internal Switch Debounce Filter: 0 to 40 Hz
CAUTION: Sustained contact closure will shorten

battery life.

RESET INPUT (contact closure to common)

Internal Pullup Resistor: 100 K

to +3.6 VDC

High (logic 1): Open or 4-30 VDC
Low (logic 0): Less Than .5 VDC
Minimum On : 25 msec
CAUTION: Sustained contact closure will shorten

battery life.

K-FACTOR

Range: 0.001 to 59999
Decimal Point Locations: XX.XXX to XXXXX
Factor Multiplier: Multiplies entered K-Factor by 1, 10, 100,
1000.

10 Point Linearization Option

This feature allows the user to enter 10 different frequencies
with 10 different corresponding K-Factors to linearize non
linear signals.

ANALOG OUTPUT:

Type: 4-20 mA follows rate display, Two wire hookup
Accuracy: 0.15% Full Scale at 20

°

C

Temperature Drift:

50 ppm/

°

C Typical

200 ppm/

°

C Worst Case

Reverse Polarity Protected

NOTE:The IT 300N uses the 4-20 mA loop power as its power

source when this output is used.

MOUNTING OPTIONS:

Explosion Proof - Class I, Division I, Groups B, C & D

Class II, Division I, Groups E, F & G

R- Wall Mount - NEMA 4X Enclosure

(unit mounted on cover)

Battery Life Expectancy

Idle

2hrs/day

8hrs/day

24hrs/day

IT 300N A

5 yrs

4.5 yrs

3.5 yrs

2.1 yrs

IT 300N A 4

5 yrs

3.7 yrs

2.7 yrs

1.5 yrs

IT 300N B/C

Standby Operation

IT 300N A/B/C

10 years

External or Loop Power

RUN TIME

PART NUMBER

All of the above values are calculated with the pulse output ON.
Turn the pulse output OFF to prolong battery life up to 30%.

5 yrs

3.7 yrs

2.7 yrs

1.5 yrs