Safety procedures – Liquid Controls CIM100 User Manual
Page 4

Before.disassembly.of.any.meter.or.accessory.component:
• all internal pressures must be relieved and all liquid drained from the system in
accordance with all applicable procedures.,
• pressure must be 0 (zero) psi.
• close all liquid and vapor lines between the meter and liquid source.
For.
Safety Rules Regarding LPG,.refer.to.NFPA Pamphlet 58.and.local.authorities.
failure to follow this warning could result in property damage, personal injury, or death from
fire and/or explosion, or other hazards that may be associated with this type of equipment.
!
WarnInG
be prepared
safely evacuate
piping system
In the event of larGe fIres or fIres that are spreadInG
n
Evacuate.the.building.and.notify.your.local.fire.department...
n
Stop.the.leakage.only.if.you.can.safely.reach.the.equipment.
In the event of sMall, contaIned fIres that you can safely
control
n
Stop.the.leakage.if.you.can.safely.reach.the.equipment...
n
Use.the.appropriate.extinguisher:.Class.B.fire.extinguisher,.water,.fog,.etc.,.
depending.on.the.materials...
n
If.in.doubt,.call.your.local.fire.department.
!
In the event of
a Gas fire
In the event of a larGe Gas leak
n
Evacuate.the.area.and.notify.the.fire.department.
In the event of a sMall, contaIned Gas leak
n
. Stop.the.leak.and.prevent.accidental.ignition.
n
. Prevent.the.entrance.of.gas.into.other.portions.of.the.buildings..Some.gases,.such.
as.LPG,.seek.lower.levels,.while.other.gases.seek.higher.levels.
n
. Evacuate.all.people.from.the.danger.zone.
n
. See.that.the.gas.is.dispersed.before.resuming.business.and.operating.motors....
If.in.doubt,.notify.your.local.fire.department.
!
In the event of
a Gas leak
safety procedures
4