Chassis intrusion digit menu select, Operation, Cim100 menu mode – Liquid Controls CIM100 User Manual
Page 11: Buttons, Indicator lights

operatIon
cIM100 Menu Mode
The.menu.mode.consists.of.12.options.for.diagnosing,.setting.up,.and.calibrating.the.CIM100..Three.small.red.buttons.
provide.the.means.to.navigate.and.edit.inside.the.menu.mode..A.fourth.red.button.switches.the.display.between.run.
and.menu.mode..Options.include:
reset chasiss Intrusion
Return.the.CIM100.to.run.mode
reset totalizer
Reset.the.resettable.totalizer
c-factor
CIM100.calibration.factor
totalizer decimal
Set.the.decimal.place.of.the.totalizers
totalizer units
Set.the.unit.of.measurement.for.the.totalizers
Input frequency lower limit
Set.a.low.flow.cut.off.frequency
Input frequency upper limit
Set.a.high.flow.cut.off.frequency
lcd test
Test.the.LCD.display
software version
View.the.CIM100.software.version
Menu lockout enable
Lock.the.menu.mode.with.a.pass.code
buttons
Chassis Intrusion
•.Run.mode.-.when.the.chassis.intrusion.button.is.pressed.down.and.held.(by.the.cover.during.normal.operation)
•.Menu.mode.-.when.the.chassis.intrusion.button.is.released
Menu
•.Scrolls.display.through.the.menu.mode.options
•.Returns.the.display.to.the.scrolling.menu.options.(after.an.option.has.been.opened)
Select
•.Opens.scrolling.menu.options.
•.Scrolls.left.to.right.through.the.eight.digit.display.when.editing.numbers—flashing.numbers.can.be.edited
Digit
•.Increases.flashing.numbers.by.one
Indicator lights
Grand
Indicates.that.the.number.displayed.on.the.totalizer.is.the.grand.total..If.this.light.is.not.on,.the.number.on.the.display.represents.the.
resettable.totalizer.
An.approximation.of.the.battery’s.power.level..As.battery.power.decreases,.the.light’s.segments.will.slowly.appear.
no light
high.power.level
one segment lit
..
low.power.level..
two segments lit.
.
replace.battery..
Gas
This.light.is.inoperable.
GallItM3
Indicates.the.unit.of.measurement.of.the.totalizer.value.
Gal
gallons.
lIt
liters.
M3
cubic.meters.
X10 or X100
Indicates.the.power.to.which.the.totalizer.value.is.multiplied.
GRAND GAS
GALLITM3 X100
Chassis
Intrusion
Digit
Menu
Select
GRAND GAS
GALLITM3 X100
Chassis
Intrusion
Digit
Menu
Select
11