Walk test recorder, Factory defaults, Delete vr – Lectrosonics VRFIELD (Narrowband) User Manual
Page 21

Digital Hybrid Wireless™ Modular Receiver System
Receivers.1&2.in.Ratio.Diversity.Mode,.Rest.in.
Switched.Diversity.Mode
Cursor.Select
Receiver.Module.
Frequency.Locations.
Clicking
Stop suspends the scan. Clicking Run re
sumes the scan. Clicking
Clear stops the scan and
clears the spectrum data.
Walk Test Recorder
The Walk Test Recorder offers a convenient method of
testing the operation of the selected receiver module (or
receiver module pair) with their corresponding transmit
ters. The Walk Test Recorder makes a chart recording
of the RF signal strength aligned with an audio record
ing of the receiver modules output.
Record.Button
Stop.Button
Use the MC65 cable (supplied with unit) to connect the
PHONES jack output on the VR Field Receiver front
panel to the computer system’s audio input.
Click the Record button to start the Walk Test Recorder
and the Stop button to stop the recording process. It is
suggested to mention locations frequently during this
test to more easily identify problem areas.
Factory Defaults
Clicking this menu item restores the selected VR Field
System to the factory default settings.
The Factory Default Settings are:
SetUpRx. Level
+00 dBu
Phase
NORMAL
TxBatt
9V ALK
SmartNR
NORMAL
PilotBP
NORMAL
Compat
Dig. Hybrid
Tuning
NORMAL MODE
DivMode
Switched
LockSet
Lockset
NOT LOCKED
Delete VR
Clicking the Delete VR menu item deletes the current
VR Field System from the VRpanel.
Rio Rancho, NM
1