2 switch settings – Controlled Products Systems Group 9050-080 User Manual
Page 34
3.2 SWITCH
SETTINGS
The DIP-switch located on the circuit board is used to program the operator to operate in various
modes and to turn on or off various operating features. Whenever a switch setting is changed, power
to the operator must be turned OFF and then turned back on for the new setting to take affect.
Check and review ALL switch settings prior to applying power to the operator.
DIP SWITCH
SWITCH FUNCTION SETTING
DESCRIPTION
1 Direction
OFF
ON
Changes open / close direction of operator.
2 Auto
Close
Timer
OFF
ON
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds.
3 Relay
OFF
ON
Relay is activated when gate is full open.
Relay is activated when gate is not closed.
4 Solenoid
Lock
OFF
ON
Fail Safe. Lock engages only when an attempt is made to force
open gate.
Fail Secure. Lock engages after each cycle.
5 & 6
Open Back Off
5-OFF 6-OFF
5-OFF 6-ON
5-ON 6-OFF
5-ON 6-ON
Normal setting. Back-off 0 inches from full open position.
Back-off 1 inch from full open position.
Back-off 2 inches from full open position.
Back-off 3 inches from full open position.
7 & 8
Close Back-Off
7-OFF 8-OFF
7-OFF 8-ON
7-ON 8-OFF
7-ON 8-ON
Normal setting. Back-off 0 inches from full close position.
Back-off 1 inch from full close position.
Back-off 2 inches from full close position.
Back-off 3 inches from full close position.
Switch 1: Set so that the operator cycles open upon initial power up and open command. If the
operator cycles close, turn power off and change the setting on this switch.
Switch 2: Turns the auto close timer on or off. Set from 1 to 23 seconds.
Switch 3: This switch determines when the relay on the board will be activated. This relay can be
used as a switch for various functions such as illuminating a warning light when the gate is not
closed, or turning on a green light when the gate is full open.
Switch 4: This switch determines the operation of the solenoid lock and is factory set. CAUTION: Do
not change the setting of this switch unless the solenoid / lock assembly has been
repositioned for the operation desired. Changing the setting of this switch without physically
changing the lock assembly will damage the operator.
Switches 5-6: These work in conjunction with each other and determine if the operator will stop the
gate at the full open position, or if the gate should stop 1, 2 or 3 inches short of the full open position.
Switches 7-8: These work in conjunction with each other and determine if the operator will stop the
gate at the full closed position, or if the gate should stop 1, 2 or 3 inches short of the full closed
position.
24