2.6 TERMINAL
IDENTIFICATION AND DESCRIPTION
2.6.1 MAIN
TERMINAL
1. EARTH
GROUND
2.
115 VAC NEUTRAL
3.
115 VAC HOT
4. MOTOR
WINDING
5. MOTOR
WINDING
6.
SOLENOID LOCK POWER
7.
RADION RECEIVER 24 VAC POWER – 250-ma MAX
8.
FULL OPEN / CLOSE INPUT
When gate is closed, input will open gate to full position.
When gate is open and auto close timer is turned on, input will re-set and hold timer.
When gate is open and auto close timer is turned off, input will close gate.
When gate is closing, input will reverse gate.
9. STANDARD
REVERSE
INPUT
When gate is fully closed or in the opening cycle, this input has no affect on the gate
operator.
When gate is open and auto close timer is turned ON, input will re-set and hold timer.
When gate is open and auto close timer is turned OFF, input will prevent gate from
closing.
When gate is closing, input will reverse gate.
10.
DRY RELAY CONTACT
Operation of relay is dependent on setting of switch 3.
When switch 3 is OFF, relay activates when gate is in the full open position.
When switch 3 is ON, relay is activated when gate IS NOT closed.
Relay contacts can be set for Normally Open (NO) or Normally Closed (NC)
operation. Contact rating is 1 amp maximum at 24 Volts.
11.
DRY RELAY CONTACT
12.
LOW VOLTAGE COMMON