Controlled Products Systems Group 104301 User Manual
Page 28

LOGIC “EP”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens the leaves
opens leaf 1
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation (1) stops operation
recloses
leaves
immediately
stops operation
immediately
reverses at
closure
no effect
stops and opens
at release
(OPEN stops -
saves CLOSE)
OPEN
recloses leaves
immediately (1)
recloses leaves
immediately
recloses
leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disa-
bled)
no effect
(OPEN/CLOSE
disabled)
CLOSING
stops operation
stops operation
no effect
stops operation
no effect
reverses at
opening
stops and opens
at release
(OPEN stops -
saves CLOSE)
BLOCKED
restarts moving in
opposite direction.
Always closes
after STOP
restarts moving in
opposite direction.
Always closes
after STOP
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disa-
bled)
no effect
(OPEN stops -
saves CLOSE)
LOGIC “AP”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens leaf 1 and
closes after pause
time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disa-
bled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
recloses
leaves
immediately
stops operation
reverses at
closing (saves
OPEN)
no effect
stops and opens
at release
(OPEN stops -
saves CLOSE)
OPEN IN PAUSE
stops operation
(1)
stops operation
recloses
leaves
immediately
stops operation
no effect
recharges
pause time
(CLOSE disa-
bled)
recharges
pause time
(CLOSE disa-
bled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect
stops operation
no effect
reverses at
opening (see
DS1-SW8)
stops and opens
at release
(OPEN stops -
saves CLOSE)
BLOCKED
closes leaves
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disa-
bled)
no effect
(CLOSE disa-
bled)
no effect
(OPEN/CLOSE
disabled)
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
LOGIC “S”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disa-
bled)
no effect
(OPEN disa-
bled)
no effect
no effect
(OPEN disabled)
OPENING
no effect (1)
no effect
recloses leaves
immediately
stops operation reverses at
closure
continues
to open and
recloses
immediately
stops and opens
at release
(saves CLOSE)
OPEN IN
PAUSE
recloses leaves
immediately (1)
recloses leaves
immediately
recloses leaves
immediately
stops operation
no effect
stops and, at
release, closes
stops and, at
release, closes
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect
stops operation
no effect
reverses at opening
(see DS1-SW8)
and closes imme-
diately at end
stops and opens
after release and
closes immediately
at end
BLOCKED
closes leaves
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disa-
bled)
no effect
(CLOSE disa-
bled)
no effect
(OPEN/CLOSE
disabled)
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
A16