FAAC Model S418 Swing Gate Operator

Fig. 24

Fig. 23

5.1

RESTORING NORMAL OPERATION

To restore normal operation mode, proceed as follows:

1. Ensure that the system is not powered.

2. Turn the release key clockwise until it stops, Figure

24 Ref. 1, and remove the key, Figure 24 Ref.

2. The locking position is indicated by a closed

padlock.

3. Close the protective cap, Figure 24 Ref. 3.

4. Manually move the leaf until the device engages

and the leaf locks.

5. Power up the system and perform several open/

close operations to check that all functions of the

automated system have been restored.

During the first cycle, the operator might not slow

down correctly. However, wait for the end of the cycle

and then give the opening command once again.

6. MAINTENANCE

In order to ensure correct operation and constant

safety over time, make a general check of the sys-

tem every six months, paying special attention to the

safety devices.

7. REPAIRS

The user must not carry out any repairs or mainte-

nance operations; these must be performed only

and exclusively by qualified FAAC personnel or

FAAC service centers.

To keep the operator in manual mode, the release

device must be left in its current (unlocked) position and

the system must not be powered.