6
TR 3
– SPEED ADJUSTMENT FOR MOTOR1 AND MOTOR 2
Turn clockwise to increase the opening and closing speed
TR 4
– SENSITIVITY ADJUSTEMENT FOR OBSTACLE DETECTION FOR MOTOR 1 AND MOTOR 2
Turn clockwise to increase the sensitivity for obstacle detection.
With this trimmer you can adjust the reaction time for the board to invert the motion of the gate in case of
obstacle detection, or the complete stop in case the board is in the positive stop detection zone.
If an obstacle is detected during the gate movement the board will invert the motor rotation until the gate goes
back to the original starting position. If in the successive movement an obstacle is detected again the board
will be put in alarm mode and won’t take any more commands until the STOP input is activated (Alarm Reset)
or power is cycled
TR 5
– PAUSE TIME ADJUSTMENT ( 0 - 4 min. )
Turn clockwise to increase the pause time.
TR6
- CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT ( 0 - 15 sec )
Turn clockwise to increase the delay
TR1
– FORCE ADJUSTMENT MOTOR 1
Turn clockwise to increase the opening and closing force
1 min
2 min
3 min
4 min
0 sec
30 sec
TR 2
– FORCE ADJUSTEMENT MOTOR 2
Turn clockwise to increase the opening and closing force
4.2 ADJUSTING TRIMMERS
Dip switches DS1: 1 to 3 need to
be set for an operating mode with
PAUSE time for this adjustment
to have any effect
A8