Install the operator – Controlled Products Systems Group -108710 User Manual
Page 9
1
x 1
90
90
0
90
90
0
90
90
0
x 1
1
A
1
1
1
1
B
TRAVEL-LIMIT
STOP AT OPE-
NING
TRAVEL-LIMIT
STOP
AT CLOSING
INSERT THE KEY WITHOUT MOVING THE PINION
AND CHECK IF IT INDICATES ZERO
TURN THE KEY UNTILL IT REACHES THE MECHANICAL
STOP-POINT AND REMOVE IT FROM THE PINION
Fig.6
Fig.4
Fig.5
Fig.3
1) Move the gate to its open position.
2) Referring to the instructions in chapter 4.1, hydraulically release
the operator, using the release screw (Fig. 3 ref.1)
3) On the operator, unscrew the plug (Fig.4 ref. A) of the screw of
the closing travel limit device (Fig.4 ref. 1) and check if the screw
is completely tight.
4) Unscrew the closing travel limit screw (Fig.4 ref. B) by
one turn (IMPORTANT FOR CORRECT COUPLING OF THE
PINION-GROOVED BUSHING DURING INSTALLATION).
5) Turn the operator pinion with the supplied wrench (Fig. 5
ref. 1),
in the gate closing direction as shown in Fig.5, up to the
internal stop point of the piston, and remove the wrench.
6)
Without moving the pinion, insert the supplied wrench on
the operator as shown in Fig.6, and make sure that it indicates 0
(ZERO) on the operator’s plastic panel (Fig.6 ref.1). If necessary
rotate the pinion. (
IMPORTANT FOR CORRECT COUPLING
OF THE PINION-GROOVED BUSH DURING INSTALLATION).
3. INSTALL THE OPERATOR
9
FAAC Model S800H Swing Gate Operator