beautypg.com

Echnical, 422 c – Controlled Products Systems Group 1042001 User Manual

Page 4

background image

Page 4

December, 2003

422 Operator And

455 D Control Panel Installation Manual

T

ECHNICAL

D

ATA

T

HE

422 C

OMPACT

O

PERATOR

Parameter

422 Standard

422 VHS

Physical dimensions:

Weight, lb (kg)

15-1/2 lb (7.0 kg)

14-1/3 lb (6.5 kg)

Length, in. (mm)

38 7/8 in. (987 mm)

32-9/16 in (827 mm)

Width ´ height, in. (mm)

3-1/2 x 4-1/2 (90 x 114mm)

3-1/2 x 4-1/2 (90x 114 mm)

Motor speed, rpm

1400

90-deg opening time, sec

12

6

Thrust and traction force, lb (kg)

0–1100 (0-500)

Hydraulic Locking

In both opened and closed positions

Cycles per hour

30

Power voltage required, VAC

(frequency, Hz)

1

115 (50–60)

+

10% or 230, +6 or -10% (50–60)

1

Current draw, amps

115v = 1.5 Amps, 230v = 1.0 Amps

Operating temperature range, deg F (deg

C)

-33 to 165 (-36 to 75)

Thermal cut out, deg F (deg C)

212 (100)

Oil quantity, qt (liter)

1 (0.9)

7/8 (0.8)

Oil type

Lubrication Engineers — MONOLEC 6105

Gate leaf constraints

Maximum weight per leaf, lb (kg)

900 (410)

440 (200)

Maximum length per leaf, ft (m)

10 (3)

4 (1.2)

Maximum gate leaf swing, deg

90

Your standard 220 VAC power source meets the specification for the

required power supply of 230 VAC, +6 or –10%.