Echnical, 422 c – Controlled Products Systems Group 1042001 User Manual
Page 4

Page 4
December, 2003
422 Operator And
455 D Control Panel Installation Manual
T
ECHNICAL
D
ATA
T
HE
422 C
OMPACT
O
PERATOR
Parameter
422 Standard
422 VHS
Physical dimensions:
Weight, lb (kg)
15-1/2 lb (7.0 kg)
14-1/3 lb (6.5 kg)
Length, in. (mm)
38 7/8 in. (987 mm)
32-9/16 in (827 mm)
Width ´ height, in. (mm)
3-1/2 x 4-1/2 (90 x 114mm)
3-1/2 x 4-1/2 (90x 114 mm)
Motor speed, rpm
1400
90-deg opening time, sec
12
6
Thrust and traction force, lb (kg)
0–1100 (0-500)
Hydraulic Locking
In both opened and closed positions
Cycles per hour
30
Power voltage required, VAC
(frequency, Hz)
1
115 (50–60)
+
10% or 230, +6 or -10% (50–60)
1
Current draw, amps
115v = 1.5 Amps, 230v = 1.0 Amps
Operating temperature range, deg F (deg
C)
-33 to 165 (-36 to 75)
Thermal cut out, deg F (deg C)
212 (100)
Oil quantity, qt (liter)
1 (0.9)
7/8 (0.8)
Oil type
Lubrication Engineers — MONOLEC 6105
Gate leaf constraints
Maximum weight per leaf, lb (kg)
900 (410)
440 (200)
Maximum length per leaf, ft (m)
10 (3)
4 (1.2)
Maximum gate leaf swing, deg
90
Your standard 220 VAC power source meets the specification for the
required power supply of 230 VAC, +6 or –10%.