beautypg.com

45 5 d c, Ontr ol, Ane l – Controlled Products Systems Group 1042001 User Manual

Page 17: Nst a llation, Nstr u c ti o n s

background image

F S W O P

F S W C L

O P _ A

O P _ B

S T O P

F C A 1

F C A 2

F C C 1

F C C 2

FSWOP

FSWCL

OP_A

OP_B

STOP

FCA1

FCA2

FCC1

FCC2

This display shows the normal

status of the control panel.

This display shows the

meaning of each LED.

Figure 13. The 455 D display.

Page 17

December, 2003

422 Operator And
455 D Control Panel Installation Manual

T

HE

45
5 D C

ONTR

OL

P

ANE

L

I

NST

A

LLATION

I

NSTR

U

C

TI

O

N

S

A

CTIVATING

D

EVICES

AND

R

ADIO

R

ECEIVER

:

The

activating devices and radio receiver for your gate must

have normally open (N.O.) contacts. Connect such

devices to terminals 9 and 14.

N

OTE

: The FAAC radio receiver plugs into the 5

prongs labeled J2 (Quick connect port).

Page 19 shows how to connect a three or four wire

receiver.

D

ECODER

C

ARD

:

If you are installing the Digicard

magnetic card reader, or the Digikey keyboard, use the

quick-fit connector J2 for the DS decoder card (see

Figure 10).

N

OTE

: If your using both a receiver and decoder,

hard wire the decoder and plug in the receiver.

O

PEN

/H

OLD

O

PEN

D

EVICE

:

To open and hold open the

gate, simply maintain a contact across terminals 9 and

14. (“A” Mode only)

S

TOP

B

UTTON

:

The stop button you install must have

normally closed (N.C.) contacts. Multiple stop buttons

must be wired in series. Connect your stop device

between terminals 11 and 16.

N

OTE

: The 455 D will not operate the motors

without a closed circuit between 11 & 16.

The LED Indicators:

The nine light emitting diodes

(LEDs) on the control panel can be used to check for the

proper function of the devices attached to the panel.

The LED lights are on whenever the contacts are closed

across each of the respective terminals.

OP_A and OP_B (Partial Opening) should illuminate only

when an activating signal is sent for 2 and 1 gate leaves,

respectively. STOP should be illuminated except when

the stop button is pressed. FSWOP and FSWCL should be

illuminated except when the reversing devices, for

Figure 12.

Wiring detail (a) inside

the junction box and (b)

from the junction box or

operator to the high-

voltage terminal strip on

the 455 D control panel

LED

On

Off

OP_A Command Given

No Command

OP_B Command Given

No Command

Stop

No Command Command Given

FSW
Open

Opening reversing

devices clear

Reversing device

triggered

FSW
Close

Closing reversing

devices clear

Reversing device

triggered

FCA1
FCC1

Flashes when gate coder is in use.

Operator 1

FCA
2
FCC
2

Flashes when gate coder is in use.

Operator 2

U.L. Listed Control Panel Enclosure

Cord grip or

conduit from

U.L. Listed gate

operator(s)

(b)

Op.1

Op.2

COM OP CL COM OP CL

J3

J4

High-voltage

terminal strip

455 D Control Panel

Ground

J1

To the U. L. Listed gate operator

To the U.L. Listed

control panel

U.L. Listed

cord grip

Junction box

Legend

White

Red

Black

Yellow/
Green

(a)

Conduit to U.L. Listed

control panel enclosure

according to N.E.C.

This manual is related to the following products: