CSB Battery UPS12580 User Manual
Powered by
Cells Per Unit
6
Voltage Per Unit
12
Capacity
580W @ 5min-rate to Watt(1.60V)/pcs @25
(77 )
Weight
Approx. 2.83 kg(6.24 lbs)
Maximum Discharge Current
130A(5sec)
Internal Resistance
Approx. 12.5m
Operating Temperature Range
Nominal Operating Temperature Range
25
3 (77
5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
3.76A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
Container Material
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
F2-Faston Tab 250
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
UPS12580
Specification
Powered by
UPS 12580 is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 5 years
in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
98.3±1.0(3.87± 0.04)
94.0±1.0 (3.70±0.04) 151.0±2.0 (5.95±0.08)
65.0±1.0 (2.56±0.04)
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
F.V/Time
2MIN
3MIN
4MIN
5MIN
6MIN
7MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
95.1
75.5
63.4
54.1
47.2
42.3
38.5
32.3
23.0
18.3
13.2
7.42
5.31
1.67V
85.3
71.0
60.2
51.7
45.6
41.2
37.6
31.7
22.7
18.1
13.0
7.33
5.20
1.70V
81.1
68.3
58.4
50.4
44.6
40.4
37.1
31.3
22.7
18.0
12.9
7.24
5.17
1.75V
73.6
62.6
53.7
47.2
42.2
38.5
35.6
30.1
22.1
17.5
12.7
7.11
5.03
1.80V
66.1
56.8
48.8
43.2
39.3
36.3
33.2
28.4
21.1
16.9
12.4
6.92
4.91
1.85V
59.4
49.7
43.5
39.3
36.3
32.9
30.3
26.1
19.6
15.8
11.7
6.61
4.70
F.V/Time
2MIN
3MIN
4MIN
5MIN
6MIN
7MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
908
774
663
580
516
469
427
361
261
208
150
84.2
59.3
1.67V
877
748
643
565
504
462
420
356
261
206
149
84.0
58.9
1.70V
859
730
630
556
499
453
414
353
258
206
149
83.6
58.8
1.75V
808
688
601
538
481
441
402
343
254
203
148
83.1
58.4
1.80V
750
640
568
505
458
419
383
329
245
197
145
81.7
57.6
1.85V
674
586
514
463
424
384
352
305
229
186
138
78.9
55.6
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.