CSB Battery EVX12200 User Manual
12v 20ah, Powered by
Cells Per Unit
6
Voltage Per Unit
12
Capacity
20Ah @ 20hr-rate to 1.75V per cell @25 (77 )
Weight
Approx 6.7 kg (14.7lbs)
Maximum Discharge Current
230A(5sec)
Internal Resistance
Approx. 14 m
Operating Temperature Range
Nominal Operating Temperature Range
25
3 (77
5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
6A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
I1-Thread lead alloy recessed terminal to accept M5 bolt
Container Material
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
EVX 12200
12V 20Ah
Specification
Powered by
EVX 12200 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
F.V/Time
30MIN
60MIN
90MIN
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
20.6
12.5
9.25
7.43
5.28
4.19
3.45
2.30
1.89
1.09
1.67V
20.0
12.3
8.99
7.25
5.15
4.10
3.35
2.23
1.85
1.06
1.70V
19.5
11.9
8.76
7.04
5.02
3.99
3.26
2.18
1.80
1.04
1.75V
18.9
11.6
8.50
6.79
4.85
3.85
3.16
2.12
1.75
1.00
1.80V
18.2
11.1
8.17
6.50
4.68
3.69
3.03
2.03
1.68
0.960
1.85V
17.4
10.6
7.84
6.22
4.49
3.52
2.89
1.95
1.62
0.920
F.V/Time
30MIN
60MIN
90MIN
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
247
150
111
88.7
63.4
50.3
41.4
27.6
22.7
12.3
1.67V
240
147
108
86.2
61.6
48.9
40.2
26.8
22.0
11.9
1.70V
233
143
105
83.7
60.0
47.5
39.1
26.0
21.5
11.7
1.75V
226
138
101
80.6
58.1
45.9
37.6
25.2
20.8
11.3
1.80V
218
133
98.0
77.4
56.1
44.3
36.3
24.3
20.1
10.8
1.85V
209
127
94.0
74.4
53.8
42.3
34.6
23.3
19.3
10.4
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
167±2 (6.57±0.08)
160±2 (6.29±0.08)
181±2 (7.13±0.08)
76.2±1 (3.0±0.04)
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.