CSB Battery EVX12300 User Manual
12v 30ah, Powered by
Cells Per Unit
6
Voltage Per Unit
12
Capacity
30Ah @ 20hr-rate to 1.75V per cell @25 (77 )
Weight
Approx. 10.4kg (22.93 lbs)
Maximum Discharge Current
400A(5sec)
Internal Resistance
Approx. 9 m
Operating Temperature Range
Nominal Operating Temperature Range
25
3 (77
5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
9 A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
I1-Thread lead alloy recessed terminal to accept M5 bolt
Container Material
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
EVX 12300
12V 30Ah
Specification
Powered by
EVX 12300 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
F.V/Time
30MIN
60MIN
90MIN
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
31.2
17.7
12.7
10.3
7.48
6.05
5.03
3.39
2.82
1.61
1.67V
30.6
17.3
12.3
9.94
7.26
5.87
4.90
3.29
2.75
1.58
1.70V
30.0
16.8
11.9
9.66
7.04
5.70
4.76
3.21
2.68
1.54
1.75V
29.2
16.3
11.6
9.38
6.83
5.54
4.64
3.12
2.61
1.50
1.80V
28.4
15.8
11.3
9.07
6.61
5.37
4.51
3.04
2.53
1.45
1.85V
27.6
15.3
10.9
8.79
6.40
5.21
4.39
2.94
2.46
1.41
F.V/Time
30MIN
60MIN
90MIN
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
374
212
152
123
89.8
72.6
60.4
40.1
33.1
17.3
1.67V
367
207
147
120
87.1
70.4
58.6
39.1
32.2
16.8
1.70V
359
202
143
116
84.5
68.4
57.1
38.1
31.4
16.4
1.75V
351
196
139
112
81.9
66.4
55.6
37.0
30.5
15.9
1.80V
341
190
135
109
79.3
64.4
54.1
35.9
29.5
15.4
1.85V
332
184
131
105
76.7
62.4
52.6
34.7
28.4
14.9
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
175±2 (6.89±0.08)
175±2 (6.89±0.08)
166.0±2 (6.53±0.08)
125.0±1.5 (4.92±0.06)
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.