CSB Battery GP12400 User Manual
12v 40ah, Powered by
Cells Per Unit
6
Voltage Per Unit
12
Capacity
40A h @ 20hr-rate to 1.75V per cell @25°C (77°F)
Weight
Approx. 12.63 kg(27.84 lbs)
Maximum Discharge Current
400A(5sec)
Internal Resistance
Approx. 8.1mΩ
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
12A
Current Limit
Equalization and Cycle Service
Self Discharge
CSB Batteries can be stored for more than 6 months at
25°C(77°F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
B2-L terminal or Recessed type to accept M5 bolt
Container Material
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15°C~50°C( 5°F~122°F)
Charge:
Storage:
Constant Power Discharge Characteristics Unit:W(25°,77°F)
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
GP 12400
12V 40Ah
Specification
Powered by
GP 12400 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
170±2 (6.69±0.08)
168.5±2 (6.63±0.08)
197±2 (7.76±0.08)
165±2 (6.5±0.08)
13.5 to 13.8 VDC/unit Average at 25°C (77°F)
14.4 to 15.0 VDC/unit Average at 25°C (77°F)
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
F.V/Time
5MIN
10MIN
15MIN
30MIN
60MIN
90MIN
2HR
3HR
5HR
8HR
10HR
20HR
1.60V
176
113
85.0
51.8
30.6
22.2
17.7
12.6
8.01
5.25
4.28
2.21
1.67V
157
105
81.0
50.8
30.3
22.1
17.6
12.5
7.98
5.19
4.19
2.11
1.70V
149
101
78.7
50.1
30.2
21.9
17.5
12.4
7.96
5.17
4.16
2.08
1.75V
135
95.0
75.5
49.0
30.0
21.8
17.4
12.3
7.93
5.10
4.09
2.00
1.80V
121
88.3
71.7
47.6
29.8
21.7
17.3
12.2
7.88
5.03
4.03
1.93
1.85V
107
81.7
67.8
46.2
29.4
21.5
17.2
12.1
7.85
4.96
3.96
1.85
F.V/Time
5MIN
10MIN
15MIN
30MIN
60MIN
90MIN
2HR
3HR
5HR
8HR
10HR
20HR
1.60V
2110
1350
1020
622
367
266
212
151
96.1
63.0
51.3
26.5
1.67V
1886
1259
972
606
364
264
211
150
95.7
62.3
50.4
25.4
1.70V
1790
1214
945
600
363
263
210
149
95.5
62.0
50.0
24.9
1.75V
1620
1140
902
585
360
262
209
148
95.2
61.2
49.2
24.1
1.80V
1450
1060
860
571
357
260
208
147
94.8
60.4
48.3
23.2
1.85V
1280
980
814
555
353
258
207
146
94.2
59.6
47.5
22.4
-15°C~40°C
-15°C~40°C
( 5°F~104°F)
( 5°F~104°F)
25°C±3°C (77°F±5°F)
RA1403
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Drawing of recessed terminal