CSB Battery HRL12500W User Manual
Powered by
PPE(UL94-V0)*Flammability resistance can
be available upon request.
I2-Thread lead alloy recessed terminal to accept M6/M8 bolt
13.5 to 13.8 VDC/unit Average at 25 (77 )
14.4 to 15.0 VDC/unit Average at 25 (77 )
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
500W @ 15min-rate to 1.67V per cell @25
o
C(77
o
F)
Approx.45.7 kg(100.75 lbs)
800A(5sec)
Approx. 3.7
m
25
o
C±3
o
C (77
o
F±5
o
F)
50A
CSB Batteries can be stored for more than 6 months at
25
o
C (77
o
F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
HRL 12500W
12V 500W
Specification
Powered by
HRL 12500W is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 10
years in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
277.7±2.5(10.93±0.10)
274.7±2.5 (10.81±0.10) 343.0 ±2.5 (13.50±0.10) 170.0±2.0 (6.69±0.08)
F.V/Time
5MIN
7.5MIN
10MIN
15MIN
20MIN
30MIN
40MIN
50MIN
60MIN
90MIN
1.60V
491
444
388
294
235
172
136
112
95.7
67.2
1.67V
449
405
356
278
223
164
134
110
94.3
66.1
1.70V
425
386
340
270
217
161
133
109
93.5
65.4
1.75V
388
348
310
253
206
155
130
107
91.1
64.5
1.80V
348
309
278
233
194
147
123
102
87.3
62.0
1.85V
304
270
247
211
179
140
115
95.3
81.1
57.3
F.V/Time
5MIN
7.5MIN
10MIN
15MIN
20MIN
30MIN
40MIN
50MIN
60MIN
90MIN
1.60V
5,275
4,691
4,167
3,181
2,594
1,951
1,558
1,292
1,112
783
1.67V
4,880
4,300
3,790
3,018
2,490
1,871
1,520
1,276
1,091
769
1.70V
4,640
4,110
3,610
2,932
2,422
1,829
1,507
1,258
1,083
763
1.75V
4,250
3,750
3,290
2,748
2,309
1,740
1,466
1,237
1,066
754
1.80V
3,830
3,340
2,950
2,497
2,138
1,657
1,390
1,186
1,025
731
1.85V
3,366
2,882
2,600
2,203
1,964
1,564
1,321
1,130
977
695
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
RA1308