CSB Battery HRL1234W User Manual
Hrl 1234w, 12v 34w, Powered by
13.5 to 13.8 VDC/unit Average at 25 (77 )
14.4 to 15.0 VDC/unit Average at 25 (77 )
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
34W @ 15min-rate to 1.67V per cell @25
o
C(77
o
F)
Approx.2.7 kg(5.95 lbs)
130A(5sec)
Approx. 17
m
25
o
C±3
o
C (77
o
F±5
o
F)
3.4A
CSB Batteries can be stored for more than 6 months at
25
o
C (77
o
F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
F2-Faston Tab 250
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
HRL 1234W
12V 34W
Specification
Powered by
HRL 1234W is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 8
years in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
98.3±1.0 (3.87±0.04)
94.0±1.0 (3.70±0.04)
151.0±2.0 (5.94±0.08)
64.8±1.0 (2.55±0.04)
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
66.0
45.0
34.5
28.0
24.0
17.6
14.0
10.1
5.69
4.00
1.67V
58.0
41.0
32.3
27.1
23.5
17.4
13.8
9.90
5.61
3.96
1.70V
54.4
39.1
31.3
26.4
23.1
17.2
13.7
9.83
5.57
3.93
1.75V
48.5
35.9
29.4
25.0
22.1
16.8
13.4
9.68
5.50
3.87
1.80V
42.5
32.8
27.0
23.2
20.6
15.8
12.8
9.33
5.36
3.80
1.85V
36.6
29.6
24.6
21.1
18.8
14.4
11.7
8.71
5.06
3.62
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
643
465
375
306
265
205
159
115
65.9
46.7
1.67V
581
435
354
299
262
204
158
114
65.4
46.6
1.70V
550
419
342
293
259
202
155
111
64.6
46.4
1.75V
503
393
324
280
251
198
152
109
63.9
46.0
1.80V
456
367
307
266
238
189
147
108
62.9
45.1
1.85V
409
341
284
246
217
174
137
102
60.2
43.4
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.