CSB Battery HRL1223W User Manual
Hrl 1223w, 12v 23w, Powered by

13.5 to 13.8 VDC/unit Average at 25 (77 )
14.4 to 15.0 VDC/unit Average at 25 (77 )
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
23W @ 15min-rate to 1.67V per cell @25
o
C(77
o
F)
Approx.2.1 kg(4.63 lbs)
130A(5sec)
Approx. 19
m
25
o
C±3
o
C (77
o
F±5
o
F)
2.3A
CSB Batteries can be stored for more than 6 months at
25
o
C (77
o
F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
F2-Faston Tab 250
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
HRL 1223W
12V 23W
Specification
Powered by
HRL 1223W is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 8
years in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
106.0±1.5 (4.17
±
0.06)
101.8±1.5 (4.01±0.06)
90.0±1.0 (3.54±0.04)
70.0±1.0 (2.76±0.04)
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
50.7
32.9
25.0
20.3
17.5
12.9
10.3
7.42
4.22
3.01
1.67V
46.7
31.4
24.2
20.0
17.3
12.8
10.2
7.35
4.18
2.99
1.70V
43.8
30.6
23.8
19.7
17.0
12.6
10.1
7.29
4.17
2.98
1.75V
39.7
28.4
22.6
19.1
16.5
12.3
10.0
7.22
4.14
2.94
1.80V
35.2
26.0
21.2
17.9
15.7
11.8
9.61
7.04
4.05
2.92
1.85V
30.6
22.8
19.1
16.2
14.3
11.0
8.99
6.58
3.85
2.78
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
497
337
264
221
192
141
114
84.4
49.8
36.5
1.67V
464
326
259
219
190
140
113
84.0
49.5
36.2
1.70V
445
317
258
217
188
139
112
83.6
49.2
36.0
1.75V
410
301
247
209
182
137
111
82.8
49.0
35.9
1.80V
373
278
233
199
175
133
109
80.8
48.1
35.3
1.85V
323
252
212
183
162
124
102
76.6
46.4
34.3
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
(http://www.csb-battery.com)
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.