beautypg.com

2dow01320199528.pdf, Hr 1251w, 12v 51w – CSB Battery HR1251W User Manual

Page 2: Charging procedures

background image

68

Charge Voltage(V/Cell)

Application

Temperature

Set Point

Allowable Range

Max.Charge Current

Cycle Use

25 (77 )

2.45

2.40~2.50

Standby

25 (77 )

2.275

2.25~2.30

0.1PA

Final Discharge

Voltage V/Cell

1.75

1.70

1.60

1.30

Discharge
Power(W)

0.1P>(W) 0.1P (W)<0.25P

0.25P (W)<1.0P

(W) 1.0P

Charging Procedures

2.60

3

0

6

9

12

15

18

2.20

2.40

2.00

1.80

1.60

1.40

0.049

0.035

0.042

0.028

0.021

0.014

0.007

140

100

120

80

60

40

20

)Ratio

1PWx15Min
1PWx7.5Min

0.025PA

2.60

3

0

6

9

12

15

18

2.20

2.40

2.00

1.80

1.60

1.40

0.049

0.035

0.042

0.028

0.021

0.014

0.007

140

100

120

80

60

40

20

)Ratio

1PWx15Min
1PWx7.5Min

0.025PA

14.70V

2.45V

HR 1251W

12V 51W

GLOBAL HQ

CSB BATTERY CO., LTD. (TAIWAN)

Tel : +886-2-2880-5600

Fax : +886-2-2888-3300

mail : [email protected]

AMERICA HQ

CSB BATTERY TECHNOLOGIES INC. (U.S.A)

Tel : +1-817-244-7777/1-(800)3-CSB-USA(272872)

Fax : +1-817-244-4445

mail : [email protected]

EUROPE HQ

CSB Battery Europe BV.

Tel : +31(0)-180-418-140

Fax : +31(0)-180-418-327

mail : [email protected]

BEIJING OFFICE. (CHINA)

CSB BATTERY TECHNOLOGIES (BEIJING) CO., LTD.

Tel : +86-10-5820-5336/5338

Fax : +86-10-58203053

mail : [email protected]

SHANGHAI OFFICE. (CHINA)

CSB BATTERY LOGISTIC (SHANGHAI) CO., LTD.

Tel : +86-21-5046-1622/5046-0833

Fax : +86-21-5064-1046

mail : [email protected]

SHENZHEN OFFICE.( CHINA )

CSB BATTERY LOGISTIC ( SHANGHAI ) CO., LTD.

Tel : +86-755-8831-6488/6396/6356

Fax : +86-755-8831-6548

mail : [email protected]