12 slim cell force ratings, Orce, Atings – Cleveland Motion Controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA User Manual
Page 13: 12 s

MAN-70434-0
R
EV
AA
U
LTRA
ISC
S
ERIES
S
LIM
C
ELL
T
RANSDUCER
Output Impedance
Approximately 64 Ohms per Bridge leg
Maximum Voltage, Gage to
Beam or Base (Ground)
50 Volts peak
Operating Temperature Range
0
o
F to +200
o
F
Maximum RPM
2500 (without derating)
Alignment
+/- 2 degrees angular displacement
Break-away torque
0.6 lb-in
1.12 S
LIM
C
ELL
F
ORCE
R
ATINGS
Size
MWF (lb.)
Linear Overload (%)*
Ultimate Overload (%) **
10 400
800
25 400
800
50 400
1000
100 300
1000
250 300
1000
UltraSlim 1
500 150
500
500 200
1000
UltraSlim 2
1000 150
500
*Linear overload: Maximum force applied on the transducer before hitting the safety stop (the output is linear up to that
point).
** Ultimate Overload: Maximum force applied on the transducer with out risking permanent deformation.
P
AGE
13
OF
42