8 operating conditions, 9 emc technical ratings, 10 emission specifications – Cleveland Motion Controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA User Manual
Page 12: 11 specifications, Perating, Onditions, Echnical, Atings, Mission specifications, Pecifications

U
LTRA
ISC
S
ERIES
S
LIM
C
ELL
T
RANSDUCER
MAN-70434-0
R
EV
AA
1.8 O
PERATING
C
ONDITIONS
Condition
Isolated Signal Conditioning Amplifier
Installation category
Category III
Pollution Pollution
Degree
2
Input supply
Earth (Ground) referenced
Protection Enclosure
mounted
1.9 EMC
T
ECHNICAL
R
ATINGS
Port
Phenomenon
Test Standard
Level
From Test Standard
Enclosure
ESD
EN 61000-4-2:
8KV AD, 1KV CD
EN 61326:1997
Enclosure
RF Field
EN 61000-4-3
10V/m,1 Khz AM
EN 61326:1997
Output Leads
Fast
Transient
Burst
EN 61000-4-4
1kV
EN 61326:1997
DC Supply
Leads
Fast
Transient
Burst
EN 61000-4-4
1kV
EN 61326:1997
DC Supply
Leads
Conducted
Immunity
EN 61000-4-6
3V/m
EN 61326:1997
Output Leads
Conducted
Immunity
EN 61000-4-6
3V/m
EN 61326:1997
1.10 E
MISSION SPECIFICATIONS
Port
Phenomenon
Test Standard
Level
Generic Standard
Enclosure Radiated
EN
61326:
1997
Class A
EN 61326:1997
The levels of performance indicated are achieved when the Isolated Signal Conditioning Amplifier is
installed by using the instructions and specifications outlined in this document.
1.11 S
PECIFICATIONS
Item:
Specification:
Transducer Weight
Slim Cell 1
Slim Cell 2
2.8 lbs.
1.3 kg
6.6 lb.
3.0 kg.
Weight + Bracket
Slim Cell 1
Slim Cell 2
5.5 lbs.
2.5 kg.
11.6 lb.
5.3 kg.
Material
Body and Side Plates – Stainless Steel 410
Bridge Resistance
135-147 Ohms @ 20
o
C
Gage Type
Semi-conductor strain gage, gage factor equals 95 (nominal)
Excitation Voltage
5.6 VDC maximum
(Excess voltage can cause permanent damage)
Nominal Output Signal at Rated
MWF
+/- 100 mV per Transducer (with 5 VDC excitation voltage)
P
AGE
12
OF
42