Stage announce and call config, Mic gain, sidetone, mic kill – Clear-Com CB-222 User Manual
Page 12
8
T-Desk Reference Manual
Stage Announce and Call Config
This sub-tab contains the Stage Announce and call feature options.
The Stage Announce audio out level can be adjusted by moving the slider bar to the left (down) or the right (up) and is
measured in decibels (dB). In addition to the audio level, you can enable or disable the Stage Relay associated with this
BaseStation.
A “call” is a signal that can be sent to other users on the Tempest Wireless system or a connected wired intercom system. The
Call Channel area allows a T-Desk user to intiate a call signal on a specific channel. The Call Config area pertains to the Call
button feature across the system and how those “calls” are handled:
y
Enable All - this allows the call feature to occur from the wireless system to the wired system and vice versa.
y
Disable All - this will prevent any call signal from occuring across the Tempest Wireless system. This only disables the call
feature on the wireless system. It does not disable a wired system’s call feature; it simply prevents the call signal from
coming into the wireless system.
y
Disable Wired - this setting allows a call signal to occur within the Tempest Wireless system, but it does not allow a signal
to come from the wired system.
y
Disable Internal - this setting disables the call feature on the Tempest Wireless system, but still allows a call signal to come
from the wired system.
Mic Gain, Sidetone, Mic Kill
This sub-tab on the BaseStation Settings tab controls the Mic Gain functionality along with the Sidetone level.
The Mic Gain sensitivity of the headset microphone (connected to the BaseStation) can be adjusted by moving the slider bar to
the left (down) or the right (up). Headset microphones may be of Electret or Dynamic type and the BaseStation automatically
detects which type is connected. The gain for each type will require significantly different settings. The BaseStation will
remember the last setting for both types of microphones. It is important to have an awareness and knowledge for the type of
headset being used before attempting to adjust Mic gain. The Mic Gain level is measured in decibels (dB).
A Mic Kill signal will disable all mics on a corresponding channel or system-wide in some cases. The Mic Kill settings control
how this feature is handled across the system:
y
Enable All - this allows the mic kill feature to occur from the wireless system to the wired system and vice versa.
y
Disable All - this will prevent any mic kill from occuring across the Tempest Wireless system. This only disables the mic kill
feature on the wireless system. It does not disable a wired system’s mic kill feature; it simply prevents the command from
coming into the wireless system.
y
Disable Wired - this setting allows a mic kill to occur within the Tempest Wireless system, but it does not allow a command
to come from the wired system.
y
Disable Internal - this setting disables the mic kill feature on the Tempest Wireless system, but still allows a command to
come from the wired system.
The Sidetone level determines how well the user hears their own voice in their headset. It can be adjusted by moving the
slider bar to the left (down) or the right (up). The Sidetone level is measured in decibels (dB).