7

T-Desk Reference Manual

Aux Levels

The Aux Levels sub-tab allows adjustment to the Aux Out audio levels. The Aux In levels are no longer adjusted at the

BaseStation; it is controlled via each BeltStation as Program Volume with individual level control. The Aux Out levels can be

adjusted for all intercom channels (A-D) and are measured in decibels (dB). To enable, move the slider bar to any value other

than “0.” Adjusting the levels to OFF disables the function for the corresponding channel.

After the relative volumes have been determined, use the “Lock Sliders” check box to sync the slider bars together so that

when one slider is adjusted, the other sliders will follow. This allows adjustment of all sliders together for occasions where the

background noise level changes significantly. When “Lock Sliders” is checked, it is good practice to use the lowest value slider

to adjust to a lower level and the highest value slider to adjust to a higher level. Otherwise, if a slider that is set to a lower

level is used to adjust to a higher volume, the lower level slider might push the higher level slider to maximum while the lower

level sliders continue to adjust higher, thus changing the relative levels.

Relays (1-5)

The Relays (1-5) sub-tab controls the 5 relay options available. Relays can act as Normal relays or in Active Channel mode.

In Normal Relay Mode, relays 1-5 can be set as normal with any of the trigger options available on the BeltStation . However,

in Active Channel Relay Mode, channels A-D activate relays 1-4 respectively. When the talk button for a channel is pressed, the

relay is closed. Relay 5 is still available to work with any other trigger options available as it would in Normal mode.

»

Channel A = Relay 1

»

Channel B = Relay 2

»

Channel C = Relay 3

»

Channel D = Relay 4

The BaseStation relays are configured under the BeltStation Settings tab, but when in Active Channel mode relays are listed as

“Relay # Not Available,” but are still selectable. If relay is selected while in this state, it will be displayed in red (and with a red

“X”) on the BeltStation status box. You can also view a snapshot of the relays condition on the above sub-tab. The relays are

numbered accordingly R

1

-R

5.

A broken link indicates an open relay that it is not currently triggered.

Open

Relay

=

Closed Relay =