beautypg.com

User programming mode – Hydrotech SXT Timer User Manual

Page 8

background image

USER PROGRAMMING MODE

User Programming Mode Options

Abbreviation

Parameter

Description

DO

Day Override

The timer’s day override setting

RT

Regeneration

Time

The time of day that the system

will regenerate (meter delayed,

timeclock, and day-of-week

systems)

H

Feed Water

Hardness

The hardness of the inlet water

- used to calculate system

capacity for metered systems

RC or SF

Reserve Capacity

The fixed reserve capacity

CD

Current Day

The current day of week

NOTE: Some items may not be shown depending on timer

configuration. The timer will discard any changes

and exit User Mode if any button is not pressed for

sixty seconds.

User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in

service, and the time of day is NOT set to 12:01 PM.

2. Use this display to adjust the Day Override. This option

setting is identified by “DO” in the upper left hand corner of

the screen.

3. Press the Extra Cycle button. Use this display to adjust the

Regeneration Time. This option setting is identified by “RT”

in the upper left hand corner of the screen.

4. Press the Extra Cycle button. Use this display to adjust the

Feed Water Hardness. This option setting is identified by

“H” in the upper left hand corner of the screen.

Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the

Fixed Reserve Capacity. This option setting is identified by

“RC” or "SF" in the upper left-hand Corner of the screen.

6. Press the Extra Cycle button. Use this display to set the

Current Day of the Week. This option setting is identified by

“CD” in the upper left hand corner of the screen.

7. Press the Extra Cycle button to end User Programming

Mode.

8 • JL10 Fleck SXT Timer