Process Data - Table 1, cont.
Process Variable Values - Integral Registers
Variable / Parameter
Modbus Slave Register
Data Type
Access
Flow MS (VALUE)
4101
SPECIAL1
READ
Flow LS (VALUE)
4102
SPECIAL1
READ
Temperature MS (VALUE)
4103
SPECIAL1
READ
Temperature LS (VALUE)
4104
SPECIAL1
READ
Totalizer MS (VALUE)
4105
SPECIAL2 (D)
READ
Totalizer MS2 (VALUE)
4106
SPECIAL2 (D)
READ
Totalizer LS2 (VALUE)
4107
SPECIAL2 (D)
READ
Totalizer LS (VALUE)
4108
SPECIAL2 (D)
READ
Pressure MS (VALUE)
4109
SPECIAL1
READ
Pressure LS (VALUE)
4110
SPECIAL1
READ
Totalizer Value - Single Precision Floating Point (16 bits)
Variable / Parameter
Modbus Slave Register
Data Type
Access
Totalizer 1 MS (VALUE)
4111
FLOAT
READ
Totalizer 1 LS (VALUE)
4112
FLOAT
READ
Totalizer 2 MS (VALUE)
4113
FLOAT
READ
Totalizer 2 LS (VALUE)
4114
FLOAT
READ
Process Variables - Engineering Unit Codes
Variable / Parameter
Modbus Slave Register
Data Type
Access
FLOW ENG. UNITS CODE
4020
INTEGER
READ
TEMP ENG. UNITS CODE
4021
INTEGER
READ
TOTALIZER ENG. UNITS CODE
4022
INTEGER
READ
PRESSURE ENG UNITS CODE
4023
INTEGER
READ
Instrument Status Codes
Variable / Parameter
Modbus Slave Register
Data Type
Access
DEVICE (SENSOR 1) STATUS CODE #1
4025
INTEGER
READ
DEVICE (SENSOR 1) STATUS CODE #2
4026
INTEGER
READ
Note: (D) indicated double precision (64 bits)
NOTE:
DATA TYPE “SPECIAL 1”: This is a collection of discrete registers that contain a single precision (32 bit)
floating point value, and must be treated and interpreted as a single precision floating point number by
the DCS or the PLC.
DATA TYPE “SPECIAL 2”: This is a collection of discrete registers that contain a double precision (64 bit)
floating point value, and must be treated and interpreted as a double precision floating point number by