Fluid Components International MT91 Manual Delta R Parameters User Manual
Page 2

FLUID COMPONENTS INTL
APPENDIX D - MT91 DELTA R PARAMETERS
Model MT91 Multipoint Flowmeter
D - 2
Doc. No. 003185 Rev. B
5.2.1 Verify Cal Inputs
URRG1
Unipolar Reference R Gain
Channel 1
URRG2
Channel 2
URRO1
Unipolar Reference R Offset
Channel 1
URRO2
Channel 2
UDRG1
Unipolar Delta R Gain
Channel 1
UDRG2
Channel 2
UDRO1
Unipolar Delta R Offset
Channel 1
UDRO2
Channel 2
BRRG1
Bipolar Reference R Gain
Channel 1
BRRG2
Channel 2
BRRO1
Bipolar Reference R Offset
Channel 1
BRRO2
Channel 2
BDRG1
Bipolar Delta R Gain
Channel 1
BDRG2
Channel 2
BDRO1
Bipolar Delta R Offset
Channel 1
BDRO2
Channel 2
RxAdj1
Reference Adjust
Output Board 1
(sensing points 1 through 8)
RxAdj2
Reference Adjust
Output Board 2
(sensing points 9 through 16)
HtAdj1
Heater Adjust
Sensing Point 1
HtAdj2
Sensing Point 2
HtAdj3
Sensing Point 3
HtAdj4
Sensing Point 4
HtAdj5
Sensing Point 5
HtAdj6
Sensing Point 6
HtAdj7
Sensing Point 7
HtAdj8
Sensing Point 8
HtAdj9
Sensing Point 9
HtAdj10
Sensing Point 10
HtAdj11
Sensing Point 11
HtAdj12
Sensing Point 12
HtAdj13
Sensing Point 13
HtAdj14
Sensing Point 14
HtAdj15
Sensing Point 15
HtAdj16
Sensing Point 16
5.2.2 Verify Cal Outputs
Zero[1]
A to D Values
Zero[2]
A to D Values
Span[1]
A to D Values
Span[2]
A to D Values
Slope[1]
A to D Values
Slope[2]
A to D Values
Off[1]
A to D Values
Off[2]
A to D Values
CorrF[1]
Correction Factor 1
CorrF[2]
Correction Factor 2
CorrF[3]
Correction Factor 3
CorrF[4]
Correction Factor 4
5.2.3.1 Verify Cal Flow Limits
FlowMin
Customer specified and factory calibrated value
for minimum flow.
FlowMax
Customer specified and factory calibrated value
for maximum flow.
TempMin
Customer specified and factory calibrated value
for minimum temperature.
TempMax
Customer specified and factory calibrated value
RRmin
Reference R minimum Calibration Value
RRmax
Reference R maximum Calibration Value
dRMin 1
Delta R minimum Calibration Value
Sensing Point 1
dRMin 2
Sensing Point 2
dRMin 3
Sensing Point 3
dRMin 4
Sensing Point 4
dRMin 5
Sensing Point 5
dRMin 6
Sensing Point 6
dRMin 7
Sensing Point 7
dRMin 8
Sensing Point 8
dRMin 9
Sensing Point 9
dRMin 10
Sensing Point 10
dRMin 11
Sensing Point 11
dRMin 12
Sensing Point 12
dRMin 13
Sensing Point 13
dRMin 14
Sensing Point 14
dRMin 15
Sensing Point 15
dRMin 16
Sensing Point 16
drMax 1
Delta R maximum Calibration Value
Sensing Point 1
drMax 2
Sensing Point 2
drMax 3
Sensing Point 3
drMax 4
Sensing Point 4
drMax 5
Sensing Point 5
drMax 6
Sensing Point 6
drMax 7
Sensing Point 7
drMax 8
Sensing Point 8
drMax 9
Sensing Point 9
drMax 10
Sensing Point 10
drMax 11
Sensing Point 11
drMax 12
Sensing Point 12
drMax 13
Sensing Point 13
drMax 14
Sensing Point 14
drMax 15
Sensing Point 15
drMax 16
Sensing Point 16